Eaton ETR-4000-2A3CA1 Transformer Relay - 50/60 Hz
Part Number: ETR-4000-2A3CA1
Quick Summary
The Eaton ETR-4000-2A3CA1 Transformer Relay protects transformers by monitoring faults and enabling fast isolation in industrial power systems. Operators frequently contend with nuisance tripping and integration friction across SCADA and Ethernet networks. This model supports Modbus TCP or DNP3 TCP/UDP over Ethernet RJ-45, accepts 19–300 Vdc or 40–250 Vac, and offers 8 digital inputs and 9 outputs. Coupled with Eaton’s warranty and service network, it helps reduce downtime and improve protection reliability across OEM and plant environments. Its rugged projection-mount design and removable terminals simplify installation, wiring checks, and field maintenance in demanding industrial settings. This combination of features supports reliable, scalable protection strategies, including zone selective interlocking and differential protection for medium-sized transformers.
Product Information
Extended Description
ETR-4000-2A3CA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Trip Coil MonitorSensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A3CA1
UPC
786679154441
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor IRIG-B Sensitive Ground Input URTD Interface
Modbus / DNP3 RTU
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Eaton Specification Sheet - ETR-4000-2A3CA1
The ETR-4000-2A3CA1 provides eight digital inputs and nine digital outputs, enabling sophisticated protection schemes and reliable signaling between relays and PLCs. This directly reduces miscoordination risk and enables precise fault isolation, limiting collateral damage during faults. Power supply flexibility is a key feature, with a 19-300 Vdc or 40-250 Vac range that eliminates the need for multiple rails and simplifies site wiring, stocking, and commissioning. Communication options include Modbus TCP or DNP3 over Ethernet RJ45, delivering real-time data, remote diagnostics, and seamless SCADA integration for plant-wide visibility and faster decision-making. The I/O options—Trip Coil Monitor, IRIG-B, Sensitive Ground Input, URTD Interface—enhance protection accuracy, timing, and synchronization in critical environments. Relationship to zone-selective interlocking (two channels) and 2 current sensing inputs enables scalable protection architectures for transformers in substations and OEM installations. Finally, removable terminals and projection mounting streamline installation and maintenance, reducing downtime during upgrades and service windows. The unit’s phase current specification (5A/1A) and differential protection capabilities align with industry standards, supporting robust fault detection without compromising system uptime. In practice, engineers report fewer false trips and faster fault clearance when combining these features with modern PLCs and SCADA dashboards, translating directly to lower operating costs and improved asset availability across production lines and distribution networks.
Get a Quick Quote for a Eaton ETR-4000-2A3CA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A3CA1?
Enquire Now
FAQs
Install the ETR-4000-2A3CA1 using its projection mounting as specified by Eaton. The device features removable terminals for straightforward wiring checks, allowing you to organize the 8 digital inputs and 9 digital outputs with minimal tooling. Ensure your DC or AC rails are within the 19-300 Vdc or 40-250 Vac range and verify Ethernet RJ45 connectivity for Modbus TCP or DNP3 communications. For best results, follow the Eaton installation guide and secure proper grounding to optimize differential protection and trip-coil monitoring capabilities.
This relay combines current sensing inputs, 8/9 I/O, zone selective interlocking, and differential protection features to enable fast, selective isolation in transformer protection schemes. Its Modbus TCP or DNP3 ethernet communication supports realtime diagnostics and integration with SCADA. With a 50/60 Hz operating range and a wide power supply window, it fits diverse substation configurations while reducing nuisance trips and improving system reliability in critical infrastructure.
Yes. The ETR-4000-2A3CA1 supports Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45, enabling seamless data exchange with contemporary control systems, HMI dashboards, and remote diagnostics. This capability helps operators monitor transformer status, perform parameter trending, and trigger alarms without onsite visits, boosting uptime and enabling proactive maintenance strategies.
Publicly listed certifications are not provided in the available data. Compliances field indicates to contact the manufacturer for definitive certification details such as CE, SIL, or IP ratings. If your project requires specific regulatory approvals, contact Eaton support or your local distributor to obtain formal certification documentation and declarations of conformity for the ETR-4000-2A3CA1.
ROI is driven by reduced downtime, fewer nuisance trips, and faster fault isolation. The 8/9 I/O configuration supports sophisticated protection logic, while the Ethernet-enabled diagnostics streamline maintenance and asset management. A typical improvement comes from higher transformer availability, lower repair costs, and faster MTTR, particularly in lines with mixed voltages and multiple transformers requiring centralized monitoring and control.