Eaton ETR-4000-2A3EB1 Transformer Relay - Profibus-DP
Part Number: ETR-4000-2A3EB1
Quick Summary
ETR-4000-2A3EB1 transformer relay protects transformers in industrial automation networks. Engineers often struggle with wiring complexity, protocol compatibility, and reliable fault signaling in harsh environments. Compliances for this model are determined by the manufacturer; verify regulatory marks such as CE/UL baselines in the official datasheet. This protection relay supports Profibus-DP over RS-485 and differential protection with current metering, delivering robust transformer protection while simplifying integration into control systems. By aligning with Eaton’s E-Series, it offers predictable maintenance costs and scalable performance for plant-wide protection strategies, leveraging 50/60 Hz operation and a wide power-supply range to reduce spare parts and inventory needs.
Product Information
Extended Description
ETR-4000-2A3EB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Profibus-DP over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz, Projection, Sensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-4000-2A3EB1
UPC
786679154601
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Profibus-DP over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input Trip Coil Monitor URTD Interface IRIG-B
Phase current
5A, 1A
PROFIBUS-DP
over D-Sub / RS-485
Sensing inputs
Differential Protection Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
0
Terminals
Removable
E-series protective relays
E-series protective relays
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Eaton Specification Sheet - ETR-4000-2A3EB1
Selling Policy 25-000 - Distribution and Control Products and Services
Feature → Business Impact → Application: 8 digital inputs and 9 outputs enable centralized protection logic and faster fault signaling, reducing decision time and downtime in medium to large transformers used in substations or process plants. Application: supports complex sequencing and interlocking across automation networks. Feature → Business Impact → Application: broad power supply range (19-300 Vdc, 40-250 Vac) accommodates diverse field devices and fluctuating plant supplies, lowering wiring changes and stocking requirements. Application: simplifies retrofits and reduces installation time in mixed-voltage environments. Feature → Business Impact → Application: Profibus-DP over D-Sub / RS-485 enables seamless integration with existing automation networks, minimizing custom interface work and enabling remote diagnostics. Application: ideal for integrated protection schemes in legacy or greenfield projects. Feature → Business Impact → Application: 2 current sensing inputs plus differential protection and metering capabilities improve protection selectivity and fault localization, reducing nuisance trips and enhancing asset longevity. Application: used for transformer differential protection and metering in industrial plants. Feature → Business Impact → Application: URTD interface, IRIG-B, sensitive ground input and trip coil monitor options provide extended monitoring and time synchronization, improving reliability and fault analysis. Application: suitable for power distribution centers and utility-grade transformer protection. Feature → Business Impact → Application: conformal coating on circuit boards enhances reliability in dusty or humid environments, lowering maintenance frequency. Application: valuable for outdoor substations and harsh factory floors. Feature → Business Impact → Application: removable terminals and projection mounting simplify installation, testing, and future maintenance, reducing labor costs and downtime. Application: practical for field upgrades and service during scheduled outages.
Get a Quick Quote for a Eaton ETR-4000-2A3EB1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-4000-2A3EB1?
Enquire Now
FAQs
Consider removable terminals and projection mounting for straightforward commissioning and maintenance. Plan for 8 digital inputs and 9 digital outputs to match your protection scheme, and ensure Profibus-DP RS485 wiring is correct for seamless network integration. Grounding, enclosure selection, and environmental protection should align with the Conformal Coated Circuit Boards specification to maximize reliability in industrial settings.
Yes. The device is designed for 50/60 Hz operation and supports a wide power supply range of 19-300 Vdc and 40-250 Vac, enabling operation across varying plant voltages without extensive reconfiguration. This flexibility helps reduce inventory needs and simplifies troubleshooting in mixed-voltage facilities.
It is ideal for transformer protection, differential protection and metering, and integration into PROFIBUS networks for centralized control. The 8 input / 9 output configuration supports complex interlocking, fault signaling, and monitoring in substations, manufacturing plants, and utility-scale transformer installations.
The product documentation indicates Compliances: Contact Manufacturer. For regulatory marks such as CE or UL, and any IP ratings, verify with Eaton’s official datasheet and support. This ensures you meet local and industry regulatory requirements before deployment.
The device consolidates protection functionality into a single relay with 8 inputs and 9 outputs, reducing wiring complexity and panel space. Removable terminals and fast-projection mounting speed installation and replacements, while 2 current sensing inputs and URTD/IRIG-B options enhance monitoring and diagnostics. Overall, this supports lower maintenance costs and higher asset uptime in continuous-operation environments.