Eaton ETR-5000-2A0CA0 Transformer Relay - Modbus TCP
Part Number: ETR-5000-2A0CA0
Quick Summary
Eaton transformer relay protects transformers in power distribution and industrial automation. Engineers face downtime and slow fault isolation when protection schemes fail to communicate essential status and diagnostics. Industry-standard protections commonly include CE marking, SIL-ready capability, and rugged IP-rated enclosures to ensure reliability in harsh environments. With Modbus TCP or DNP3 over Ethernet RJ45 and removable terminals, this relay enables fast integration and proactive maintenance. Its wide power range and 8 inputs / 9 outputs, plus compatibility with the ETR-4000 base, translates to lower installation cost and easier commissioning. Perfect for OEMs and service providers.
Product Information
Extended Description
ETR-5000-2A0CA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9, Removable, Transformer, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A0CA0
UPC
786679158814
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor URTD Interface IRIG-B
Modbus / DNP3 RTU
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Voltage Protection and Metering Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Eaton Specification Sheet - ETR-5000-2A0CA0
Selling Policy 25-000 - Distribution and Control Products and Services
Wide power supply range and 50/60 Hz compatibility enable global deployments with a single unit. This reduces spare parts and simplifies procurement across regional sites while easing stocking and training. Ideal for substations, data centers, and OEM equipment where both DC and AC sources must be monitored. Eight digital inputs and nine digital outputs with removable terminals streamline wiring and maintenance. This arrangement supports faster commissioning, easier field upgrades, and reduced risk of loose connections, enabling reliable signaling and actuator control across protection zones. I/O options such as Trip Coil Monitor, URTD Interface, and IRIG-B provide extended diagnostics and timing coordination. This enhances anomaly detection, time synchronization, and compatibility with mission-critical protection architectures in utility substations and industrial installations. Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45 enables remote SCADA integration. The result is centralized monitoring that reduces on-site visits and accelerates fault diagnosis for OEMs and utilities. Phase current options of 5A and 1A, plus two current-sensing inputs, support accurate protection setpoints across transformer ratings. This translates to precise fault signaling and reduced nuisance trips in distribution networks. Removable terminals and semi-flush mounting further simplify installation and serviceability, delivering faster time-to-value for engineering teams.
Get a Quick Quote for a Eaton ETR-5000-2A0CA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2A0CA0?
Enquire Now
FAQs
Begin by confirming the unit’s power supply range and mounting requirements. Connect the eight digital inputs and nine digital outputs through the removable terminals according to your protection scheme. Use the Modbus TCP or DNP3 over Ethernet RJ45 interface for SCADA integration, then configure trip setpoints and diagnostic logging with Eaton’s configuration tools. Ensure proper grounding and enclosure integrity to maintain signal quality.
Key specs include a power supply range of 19-300 VDC and 40-250 VAC, with a 50/60 Hz frequency rating. It features two current sensing inputs, phase currents of 5A and 1A, eight digital inputs, and nine digital outputs. Communication is via Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45. Terminals are removable, supporting reliable field installation and maintenance.
Substations and utility-scale transformer protection are primary applications, along with OEM equipment and data centers requiring reliable transformer monitoring. The device’s wide power range, remote communication options, and flexible I/O enable integration into existing protection architectures and SCADA systems, reducing downtime, improving fault clarity, and supporting time-critical protection schemes.
Current product data indicates ‘Compliances: Contact Manufacturer,’ so consult the Eaton specification sheet for definitive regulatory details. In practice, transformer protection relays used in critical infrastructure typically address CE marking, SIL readiness, and rugged enclosure standards. Always verify with Eaton’s datasheets and regional certifications to ensure compliance for your installation site.
Remote monitoring via Modbus TCP/DNP3 reduces field visits by enabling centralized diagnostics and proactive maintenance. The unit’s removable terminals simplify serviceability, while compatibility with the ETR-4000 base supports scalable upgrades without complete system rewrites. Expect lower downtime, faster fault resolution, and a shorter time-to-value for transformer protection initiatives.