Eaton ETR-5000-2A0GB1 Transformer Relay - Modbus RTU

Part Number: ETR-5000-2A0GB1
Manufacturer
Eaton
Part number
ETR-5000-2A0GB1

Quick Summary

Eaton transformer relay protects transformers and monitors critical protection functions for industrial power systems. Design teams often struggle to integrate protection logic with Modbus RTU or DNP3 RTU over RS-485 while keeping fault isolation fast and reliable. Certification visibility for this model isn’t published; confirm SIL, CE, or IP ratings with Eaton as needed. With eight digital inputs, nine outputs, and dual power ranges of 19–300 Vdc and 40–250 Vac, this device enables scalable protection and metering across equipment fleets, reducing downtime and simplifying commissioning in substations and industrial plants.

Product Information

Extended Description

ETR-5000-2A0GB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A0GB1
UPC
786679156230
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor URTD Interface IRIG-B
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Differential Protection Power Protection and Metering Current Protection and Metering Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Communication interfaces are designed for seamless integration; Modbus RTU or DNP3 RTU over RS-485 enables reliable plant-wide monitoring and remote control, reducing wiring complexity and speeding up commissioning while improving data accuracy for transformer protection assets. This directly lowers operational risk and supports SCADA interoperability, essential for large substations and OEM equipment deployments. The 8 digital inputs and 9 outputs provide ample I/O headroom to implement advanced protection schemes without expanding cabinet footprint, delivering tangible space and cost savings while enhancing fault isolation capabilities. The 2 current sensing inputs support differential and metering functions, enabling precise protection coordination and power quality monitoring, which reduces false trips and improves energy management. Power is flexible across 19–300 Vdc and 40–250 Vac with 50/60 Hz compatibility, simplifying retrofit projects and minimizing electrical infrastructure rewiring. The unit’s projection mounting and removable terminals streamline installation and service, minimizing downtime during upgrades while maintaining robust field reliability. Conformal coating further enhances resilience in harsh industrial environments, supporting long-term performance and reducing maintenance costs. The ETR-4000 base relay compatibility and options for Trip Coil Monitoring, URTD interface, and IRIG-B time synchronization provide a scalable path for future protection enhancements, aligning with evolving grid and plant automation standards.

Get a Quick Quote for a Eaton ETR-5000-2A0GB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A0GB1? Enquire Now

FAQs

Plan for projection mounting and removable terminals to simplify retrofits. Ensure panel depth accommodates an 8.06 in length and 9.72 in width footprint. Leverage base compatibility with ETR-4000 and use the conformal-coated circuit boards in harsh environments. Confirm wiring practices align with RS-485 Modbus or DNP3 RTU interfaces to minimize interference and optimize commissioning time.
Key specs include 8 digital inputs and 9 outputs with 2 current sensing inputs for differential protection and metering. The power supply range covers 19–300 Vdc and 40–250 Vac, operating at 50/60 Hz. Communication is via Modbus RTU or DNP3 RTU over RS-485, enabling robust SCADA integration and fast fault isolation in transformer protection schemes.
Yes. It provides transformer protection, metering, and remote communication suitable for substations and industrial plants. Its 8/9 IO and Modbus/DNP3 interfaces support scalable protection coordination, while the 50/60 Hz compatibility and wide power ranges ease integration with existing electrical gear and control systems in both new builds and retrofit projects.
Public certifications are not listed in the provided data; the Compliances field indicates 'Contact Manufacturer.' If your project requires SIL, CE, or IP classifications, confirm with Eaton directly to obtain the exact certifications and any application notes relevant to your installation or regional regulatory requirements.
Eaton provides a standard warranty per policy 25-000: one year from installation or 18 months from shipment, whichever occurs first. For field support and spares, contact Eaton’s technical support. This warranty underpins predictable maintenance and smooth lifecycle management for transformer protection relays in critical equipment fleets.