Eaton ETR-5000-2A0HB0 Transformer Relay - 61850
Part Number: ETR-5000-2A0HB0
Quick Summary
The Eaton transformer relay ETR-5000-2A0HB0 delivers comprehensive transformer protection for distribution and industrial networks. Engineers often grapple with coordinating protection schemes, device interoperability, and remote diagnostics across evolving automation architectures. Its support for 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet enables modern substation integration while preserving legacy compatibility. From a procurement perspective, the device’s flexible I/O, modular options, and a one-year warranty help reduce lifecycle costs and downtime. The product’s conformal coating and removable terminals support harsh environments and straightforward field maintenance. With digital I/O counts of eight inputs and nine outputs, engineers can tailor protection logic to transformer ratings and site requirements.
Product Information
Extended Description
ETR-5000-2A0HB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A0HB0
UPC
786679156285
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Trip Coil Monitor IRIG-B
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Differential Protection Current Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
E-series protective relays
E-series protective relays
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Eaton Specification Sheet - ETR-5000-2A0HB0
Feature → Business Impact → Application: Protocol-driven protection is enabled by multi‑protocol communications, reducing engineering time and wiring changes while allowing seamless integration with existing protection schemes and modern automation systems. This supports faster commissioning and lowers project risk in substations and plant retrofit scenarios. Application: transformer protection with 61850, Mbus TCP, and DNP3 TCP/UDP over Ethernet RJ45. Feature → Business Impact → Application: Eight digital inputs, nine digital outputs, and two current sensing inputs provide flexible protection logic for a broad range of transformer configurations. This enables precise metering, differential protection, and power protection without external add-ons. Application: customized protection schemes for transformers in utilities and industrial facilities. Feature → Business Impact → Application: Power supply ranges of 19-300 Vdc or 40-250 Vac with 50/60 Hz operation support installation across diverse geographies. Removable terminals and conformal-coated boards simplify field wiring and maintenance, increasing reliability in challenging environments. Application: rugged deployments with URTD Trip Coil Monitor and IRIG-B timing for coordinated protection. Feature → Business Impact → Application: Semi-flush mounting and a robust mechanical design reduce installation time and spare parts needs. Ethernet-based diagnostics and firmware updates enable remote maintenance, lowering on-site labor costs. Application: scalable protection for large transformer banks in substations and manufacturing plants. Feature → Business Impact → Application: Zone Selective Interlocking (ZSI) channels enable coordinated tripping to minimize outages, improving reliability and reducing system-wide disturbance. Combined with metering and protection logic, ZSI supports optimized protection selectivity. Application: complex transformer networks requiring fast, selective fault isolation.
Get a Quick Quote for a Eaton ETR-5000-2A0HB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2A0HB0?
Enquire Now
FAQs
Installation of the ETR-5000-2A0HB0 should start with verifying supply compatibility and planning the eight digital inputs and nine outputs to match your protection scheme. Use the removable terminals for clean field wiring and follow proper cabling practices for Ethernet-based communications. Position the relay for easy access to URTD/IRIG-B options and ensure 61850 or DNP3/TCP network connectivity is established.
ETR-5000-2A0HB0 supports 61850, Mbus TCP, and DNP3 TCP/UDP over Ethernet RJ45, enabling seamless integration with modern automation architectures. This multi-protocol capability reduces engineering effort by preserving existing interfaces while enabling centralized monitoring and remote control. Pair with compatible SCADA or protection schemes to realize faster fault isolation and improved situational awareness.
Yes. The ETR-5000-2A0HB0 includes zone selective interlocking (ZSI) with two interlocking channels, enabling coordinated tripping across transformer banks. This improves reliability by restricting faults to the affected zone and reducing outage times. Combine ZSI with the relay’s metering and protection features to optimize protection selectivity. It also supports flexible mounting and Ethernet-based remote monitoring to verify interlocking status.
The unit accepts a dual power range of 19-300 Vdc or 40-250 Vac and operates at 50/60 Hz, simplifying installation across diverse sites. It provides eight digital inputs and nine digital outputs, plus two current-sensing inputs, enabling robust protection logic and metering across transformer circuits. Removable terminals and conformal-coated boards enhance field service and reliability in harsh environments.
The Eaton policy provides a one-year warranty from the installation date or eighteen months from shipment, whichever comes first, backing performance and service. For maintenance, consult Eaton's spare parts and service programs to plan firmware updates, diagnostics, and on-site or remote support, ensuring long-term protection reliability and availability for uptime.