Eaton ETR-5000-2A0LA0 Transformer Relay - DNP3 TCP/LC Fiber

Part Number: ETR-5000-2A0LA0
Manufacturer
Eaton
Part number
ETR-5000-2A0LA0

Quick Summary

The Eaton transformer relay protects transformer circuits in industrial power systems, providing real-time monitoring and fault-tripping. Unplanned outages and costly repairs are common when protection relays fail to respond quickly. Certification details such as CE, SIL or IP ratings are not listed here; contact Eaton for exact certifications. The device supports Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet, 8 digital inputs, 9 outputs, and 5A/1A current sensing for scalable transformer protection. This enhances system uptime and diagnostics while simplifying integration with existing control architectures.

Product Information

Extended Description

ETR-5000-2A0LA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz ,Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A0LA0
UPC
786679156896
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Trip Coil Monitor IRIG-B
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Voltage Protection and Metering Power Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature → Business Impact → Application: 8 digital inputs and 9 digital outputs deliver comprehensive input/output control for protection logic, enabling precise fault detection and faster isolation in substations and OEM equipment. This reduces downtime and extends transformer life by ensuring timely protective actions. Application: Industrial power distribution where robust IO is essential. Feature → Business Impact → Application: Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet provides secure, low-latency communication and remote monitoring, supporting asset management and predictive diagnostics. Application: Remote sites and distributed assets requiring reliable data exchange. Feature → Business Impact → Application: A power supply range of 19-300 Vdc and 40-250 Vac at 50/60 Hz enables flexible installation across varying plant power sources, simplifying panel design and onboarding. Application: Mixed DC/AC supply environments. Feature → Business Impact → Application: URTD Trip Coil Monitor IRIG-B I/O options extend protection visibility and trip verification, reducing misoperations and enabling precise fault tracing. Application: Critical transformer protection in high-stakes installations. Feature → Business Impact → Application: Removable terminals and semi-flush mounting streamline installation and maintenance, cutting commissioning time and enabling easier retrofits. Application: Retrofit projects and new builds with tight installation schedules. Feature → Business Impact → Application: Warranty and data-rich diagnostics under Eaton policies provide long-term support and documentation, reducing total cost of ownership. Application: Asset lifecycle management in facilities and utilities.

Get a Quick Quote for a Eaton ETR-5000-2A0LA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A0LA0? Enquire Now

FAQs

Installers should mount the unit using its semi-flush mounting and connect wiring through removable terminals for easy service. With 8 digital inputs and 9 outputs, confirm correct I/O mapping to your protection logic, and use the URTD option and IRIG-B where trip verification is required. Ensure the power supply is within 19–300 Vdc or 40–250 Vac and follow the chassis labeling for safe enclosure integration.
The ETR-5000-2A0LA0 supports Mbus TCP or DNP3 TCP/UDP over LC duplex fiber optic Ethernet, enabling secure, low-latency data exchange and remote diagnostics. This compatibility facilitates integration with modern SCADA, MES, and asset management systems while maintaining robust field communications.
Yes. The device supports a power supply range of 19–300 Vdc and 40–250 Vac with a 50/60 Hz rating, allowing flexible operation across varied plant power architectures. This makes it well-suited for mixed DC/AC systems in industrial facilities and substations.
Warranty is governed by Eaton’s selling policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. For ongoing support, refer to Eaton documentation and request certification details if needed. This provides a defined support window and documented protection in capital projects.
The ETR-5000-2A0LA0 combines eight digital inputs, nine outputs, two current sensing inputs, and versatile communication over fiber with a broad power range. This enables fast fault detection, secure remote monitoring, and straightforward installation, translating to reduced downtime, precise protection, and simpler lifecycle management for transformers in utilities and industrial plants.