Eaton ETR-5000-2A0LA1 Transformer Relay - 50/60 Hz

Part Number: ETR-5000-2A0LA1
Manufacturer
Eaton
Part number
ETR-5000-2A0LA1

Quick Summary

The Eaton transformer relay provides protective monitoring for transformer circuits in industrial power systems. Operators often struggle with integrating protection data across diverse protocols and remote locations, which slows fault isolation and increases risk. Common certifications for this class of device include CE marking, SIL readiness, and IP-rated enclosures; verify approval for this model with Eaton. With built-in Mbus TCP or DNP3 TCP/UDP over LC fiber and versatile I/O options, it simplifies diagnostics, SCADA integration, and remote access. By consolidating protection, metering, and communications in one package, it shortens commissioning time and reduces maintenance costs across industrial sites. This makes it a reliable backbone for modern digital substations.

Product Information

Extended Description

ETR-5000-2A0LA1 Eaton: Eaton transformer relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection, URTD Interface, Trip Coil Monitor, IRIG-B
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A0LA1
UPC
786679156919
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Trip Coil Monitor IRIG-B
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Differential Protection Current Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Feature: Mbus TCP or DNP3 TCP/UDP over LC duplex fiber enables secure, standards-based communication. Business impact: enhances remote monitoring and data integrity, reducing field visits and enabling faster fault diagnosis. Application: suitable for substations, OEM equipment, and distributed power systems. Feature: 8 digital inputs and 9 digital outputs plus 2 current sensing inputs streamline protection logic and metering without adding external hardware. Business impact: enables comprehensive transformer protection schemes with fewer components, cutting installation time and lifecycle costs. Application: ideal for transformer protection relays within industrial power distribution. Feature: power supply range of 19-300 Vdc and 40-250 Vac with 50/60 Hz support provides flexible installation across varying plant voltages. Business impact: simplifies site wiring, ensures compatibility with existing MCCs, and improves uptime. Application: retrofit projects and new builds alike. Feature: URTD Interface, Trip Coil Monitor, and IRIG-B options expand diagnostics and time synchronization capabilities. Business impact: improves sequence protection accuracy and event logging, reducing miscoordination. Application: critical in zone selective interlocking and remote diagnostics. Feature: Projection mounting and removable terminals improve ease of installation and serviceability. Business impact: reduces commissioning time and maintenance labor. Application: field service and OEM assembly lines. Feature: Warranty and support through Eaton policy provides a clear service commitment. Business impact: lowers total cost of ownership by simplifying maintenance planning and minimizing unexpected downtime. Application: industrial installations with strict uptime requirements.

Get a Quick Quote for a Eaton ETR-5000-2A0LA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A0LA1? Enquire Now

FAQs

Consider projection mounting and removable terminals for quick field servicing. Plan wiring to accommodate 8 digital inputs and 9 digital outputs, plus 2 current sensing inputs. Ensure the power supply source is within 19-300 Vdc or 40-250 Vac and that the fiber optic LC link for Mbus TCP or DNP3 TCP/UDP is properly terminated. Verify adequate clearance for heat dissipation and provide secure mounting to minimize vibration impact in industrial environments.
Key specs include 19-300 Vdc and 40-250 Vac power supply, 50/60 Hz frequency, 8 digital inputs, 9 digital outputs, and 2 current sensing inputs. Communication is via Mbus TCP or DNP3 TCP/UDP over LC duplex fiber. The device supports transformer protection functions with URTD interface options and IRIG-B time signaling, enabling precise sequencing and diagnostics in demanding power systems.
Yes. The model lists URTD Interface, Trip Coil Monitor, and IRIG-B as I/O options, enabling enhanced diagnostics and time synchronization. This makes it well-suited for precise protective coordination in zone selective interlocking and large-scale transformer protection schemes, while ensuring accurate event logging and coordinated tripping across distributed assets.
Compliance details are provided by the manufacturer; confirm CE marking, SIL readiness, and IP ratings directly with Eaton for this specific model. The product also carries an Eaton warranty policy (one year from installation or eighteen months from shipment, whichever occurs first) which helps manage maintenance planning and total cost of ownership in industrial deployments.
The relay consolidates protection, metering, and communications into a single package, reducing field hardware and installation time. Remote diagnostics via Mbus TCP and DNP3 TCP/UDP minimize site visits, accelerating fault isolation and commissioning. Over the lifecycle, this translates to lower maintenance labor, reduced downtime, and faster return on investment in substations and OEM equipment.