Eaton transformer relay ETR-5000-2A1BA1 - RS485 Modbus/DNP3

Part Number: ETR-5000-2A1BA1
Manufacturer
Eaton
Part number
ETR-5000-2A1BA1

Quick Summary

Eaton transformer relay ETR-5000-2A1BA1 enables protection and monitoring for power transformers in industrial facilities. When protection coordination and remote diagnostics are required across RS-485 networks, engineers need a single, reliable device that minimizes wiring and reduces nuisance trips. Formal certifications such as CE, UL, or IP ratings should be confirmed with the manufacturer for regional compliance. With a wide power range and Modbus RTU or DNP3 RTU over RS485, the ETR-5000-2A1BA1 supports retrofit upgrades and new installations alike. This transformer protection relay combines 8 digital inputs, 9 outputs, and robust communication options to improve visibility, control, and overall system uptime.

Product Information

Extended Description

ETR-5000-2A1BA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A1BA1
UPC
786679157121
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input URTD Interface Trip Coil Monitor IRIG-B
Modbus / DNP3 RTU
over RS-485
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Current Protection and Metering Power Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Modbus RTU or DNP3 RTU over RS485 enables seamless PLC/SCADA integration, reducing commissioning time and enabling centralized fault logging in transformer protection schemes. This configuration is ideal for retrofitting existing protection equipment in substations or OEM power modules, delivering faster fault isolation and easier data exchange with the control system. 8 digital inputs and 9 digital outputs provide ample I/O for supervision, tripping schemes, and interlocking without the need for extensive external modules, which lowers panel space requirements and wiring complexity while boosting reliability. The wide power supply range of 19-300 VDC and 40-250 VAC supports both new installations and legacy plant voltages, simplifying procurement and inventory management while ensuring compatibility across multiple sites. The device offers 50/60 Hz frequency support and dual current sensing inputs, enabling accurate protection coordination and metering across diverse electrical networks. I/O options such as Sensitive Ground Input, URTD Interface, Trip Coil Monitor, and IRIG-B allow advanced fault correlation, faster event reconstruction, and precise time synchronization for diagnostics and compliance reporting. Removable terminals and projection mounting simplify installation, commissioning, and future servicing, reducing downtime during upgrades and enabling clean, scalable protection architectures. Zone selective interlocking (ZSI) capability further enhances selectivity, improving system reliability and reducing the impact of faults on downstream equipment. Overall, the ETR-5000-2A1BA1 delivers a compact, feature-rich solution that aligns protection performance with modern industrial workflows, supporting both OEMs and utilities in achieving safer, more efficient transformer protection.

Get a Quick Quote for a Eaton ETR-5000-2A1BA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A1BA1? Enquire Now

FAQs

The ETR-5000-2A1BA1 uses projection mounting with removable terminals, enabling straightforward panel installation and simpler field servicing. This design supports quick wiring changes and reliable contact integrity, while the 8 digital inputs and 9 digital outputs provide ample local I/O to support protection logic without additional interface modules.
The relay supports Modbus RTU or DNP3 RTU over RS485, enabling direct integration with most PLCs and SCADA systems. This minimizes engineering time, allows centralized fault logging, and supports coordinated protection across transformer circuits without requiring custom adapters.
The ETR-5000-2A1BA1 accommodates a wide range of power inputs: 19-300 VDC and 40-250 VAC, with 50/60 Hz operation. This flexibility simplifies retrofits and new installations across facilities with mixed electrical systems, reducing the need for multiple power supply variants.
Yes. It offers voltage protection and metering, current protection and metering, power protection and metering, and differential protection. With 2 current sensing inputs and multiple I/O options (Sensitive Ground Input, URTD Interface, Trip Coil Monitor, IRIG-B), you gain robust protection coordination and detailed event data for diagnostics and reporting.
Official documentation, brochures, and the specification sheet are available via Eaton’s downloads. Look for the Eaton Specification Sheet – ETR-5000-2A1BA1 and related brochures, plus the Power metering and diagnostics PDFs for OEM applications and system integration guidance.