Eaton ETR-5000-2A1GA1 Transformer Relay - Modbus RTU / DNP3 RTU

Part Number: ETR-5000-2A1GA1
Manufacturer
Eaton
Part number
ETR-5000-2A1GA1

Quick Summary

Eaton transformer relay is a protection device that monitors transformer circuits in industrial power systems. Many buyers struggle with timely fault detection and fast isolation while keeping downtime to a minimum. Certification details vary by installation; see the official Eaton specification sheet to confirm CE, SIL, IP ratings and regional approvals. This solution delivers reliability and scalability for transformer protection in plant-wide automation, with Modbus/DNP3 communication enabling seamless integration and improved asset uptime.

Product Information

Extended Description

ETR-5000-2A1GA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, D-Sub/RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A1GA1
UPC
786679157947
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface IRIG-B Trip Coil Monitor Sensitive Ground Input
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Current Protection and Metering Differential Protection Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Eight digital inputs and nine outputs give you expansive monitoring and signaling capability, while two current sensing inputs enable precise fault detection and metering. This translates to faster protection decisions and reduced risk of transformer damage, supporting operations across manufacturing, utilities, and data centers. The wide power-supply range of 19-300 VDC and 40-250 VAC at 50/60 Hz ensures easy integration with existing plant power rails, minimizing wiring redundancy and simplifying retrofit projects. Modbus RTU or DNP3 RTU over RS-485 provides interoperable communication with SCADA and MES systems, improving visibility and control without extra gateway hardware. Removable terminals and projection mounting simplify installation, maintenance, and field upgrades, reducing total cost of ownership. I/O options such as URTD Interface, IRIG-B Trip Coil Monitor, and Sensitive Ground Input enable advanced protection schemes and precise timing for critical feeders. Zone selective interlocking (2) supports coordinated protection, improving selectivity and minimizing outage scope in substations and multi-bus configurations. This combination delivers measurable efficiency gains, compliance assurance, and a clear path to scalability as your protection strategy evolves.

Get a Quick Quote for a Eaton ETR-5000-2A1GA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A1GA1? Enquire Now

FAQs

Install the transformer relay with the D-Sub/RS-485 interface as documented in the Eaton spec sheet. Use the eight digital inputs and nine outputs to synchronize with your PLC or SCADA, ensuring the bus termination and addressing match your network topology. The removable terminals simplify field wiring, and the projection mounting supports compact panel layouts.
Verify power supply range (19-300 Vdc, 40-250 Vac) and frequency (50/60 Hz), eight digital inputs, nine outputs, and two current sensing inputs. Ensure the communication interface is set to Modbus RTU or DNP3 RTU over RS-485, and confirm terminal accessibility for easy commissioning and future upgrades.
Yes, the model supports zone selective interlocking with a capability value indicated as 2, enabling coordinated protection across multiple feeders. This improves selectivity, reduces outage impact, and helps meet substation protection coordination requirements when integrated with compatible relays and control systems.
Compliance details are provided by the manufacturer and may vary by region. Consult the Eaton specification sheet and regional approvals to confirm CE, SIL, IP ratings, and any UL/CSA requirements applicable to your installation.
The ETR-5000-2A1GA1 consolidates protection, metering, and remote communication, reducing downtime and maintenance visits. Its removable terminals and robust modular I/O simplify diagnostics, while Modbus/DNP3 interoperability lowers integration costs. Regular software/firmware updates and adherence to the Eaton warranty policy help sustain long-term reliability and predictable operating expenses.