Part Number: ETR-5000-2A1GB1
Quick Summary
Eaton transformer relay ETR-5000-2A1GB1 delivers robust transformer protection for industrial power systems. This unit is designed to accurately detect faults and enable rapid isolation to minimize downtime. Certification details vary by region, with CE, SIL, and IP-related approvals commonly pursued for transformer protection relays; exact ratings are available from Eaton. The device supports Modbus RTU or DNP3 RTU communications over RS-485, along with a broad power-supply range of 19-300 VDC or 40-250 VAC, enabling flexible integration with existing controls. By combining 8 digital inputs and 9 digital outputs with rugged construction and conformal coating, this relay offers reliable operation in demanding environments and clear business value for OEMs and maintenance teams.
Product Information
Extended Description
ETR-5000-2A1GB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over D-SUB/RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A1GB1
UPC
786679158111
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor URTD Interface IRIG-B Sensitive Ground Input
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Eaton Specification Sheet - ETR-5000-2A1GB1
Feature: 8 digital inputs, 9 digital outputs, plus 2 current sensing inputs. Business Impact: Enables rich protection logic, status signaling, and coordinated trip operations without extra hardware. Application: Transformer protection schemes in substations and plant switchgear where detailed I/O is needed. The I/O density reduces panel wiring and enables faster commissioning. Feature: Removable terminals and projection mounting. Business Impact: Streamlines installation, field servicing, and future upgrades, cutting downtime during maintenance. Application: OEM assemblies and retrofit projects that demand quick, reliable wiring. Feature: Modbus RTU or DNP3 RTU over RS-485. Business Impact: Facilitates seamless remote monitoring and integration with SCADA/EMS software, improving visibility and control. Application: Industrial power distribution centers and OEM control cabinets. Feature: Power supply range 19-300 VDC / 40-250 VAC and 50/60 Hz. Business Impact: Supports diverse plant power architectures, reducing the need for multiple power modules. Application: Global deployments with mixed supply environments. Feature: Conformal coated circuit boards and 8-input/9-output architecture. Business Impact: Enhances reliability in humid, dusty, or harsh environments, extending service intervals. Application: Harsh manufacturing floors and outdoor substations. Feature: Base compatibility with ETR-4000; easy upgrade path. Business Impact: preserves investment and simplifies migration to newer protection features. Application: Refurbishment and expansion projects where legacy systems are present.
Get a Quick Quote for a Eaton ETR-5000-2A1GB1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2A1GB1?
Enquire Now
FAQs
The ETR-5000-2A1GB1 supports Modbus RTU or DNP3 RTU communications over RS-485, uses removable terminals for easy wiring, and provides 8 digital inputs with 9 digital outputs plus 2 current-sensing inputs. It is designed to drop into standard transformer protection panels and integrates with existing D-SUB RS-485 networks, simplifying field deployment.
Power supply range covers 19-300 VDC or 40-250 VAC with a 50/60 Hz frequency rating. The device accommodates 5 A or 1 A channel ratings on phase current sensing and provides multiple protection I/O pathways (8 inputs, 9 outputs) to support complex transformer protection schemes and metering needs.
Yes. The ETR-5000-2A1GB1 is purpose-built as a transformer protection relay with modular I/O, RS-485 communication, and compatibility with common SCADA interfaces. Its 8 DI/9 DO and 2 current sensing inputs support differential protection, power protection and metering, enabling fast fault isolation and secure remote monitoring in substations and OEM equipment.
Compliance details for this model are listed as 'Contact Manufacturer' in the data set, with CE, SIL, and IP-related certifications commonly pursued for transformer relays in this class. For exact approvals and country-specific requirements, confirm with Eaton or your local distributor before procurement.
The relay’s robust protection, removable terminals, projection mounting, and conformal-coated boards reduce commissioning time and maintenance downtime. RS-485 remote monitoring via Modbus/DNP3 lowers field visits, while the 1-year (or 18-month from shipment) Eaton warranty mitigates risk. All these factors contribute to lower lifecycle costs and quicker return on investment.