Eaton ETR-5000-2A1HA0 Transformer Relay - 61850 TCP/UDP

Part Number: ETR-5000-2A1HA0
Manufacturer
Eaton
Part number
ETR-5000-2A1HA0

Quick Summary

The Eaton transformer relay ETR-5000-2A1HA0 protects transformer assets while enabling real-time monitoring in utility-scale and industrial power systems. Engineers often struggle with coordinating protection logic, data collection, and remote diagnostics across disparate devices. This model supports 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet, with wide input ranges of 19-300 VDC and 40-250 VAC and multiple I/O for flexible protection schemes. Compliance information is provided by the manufacturer; verify CE, UL, or other regional certifications for your installation. By consolidating protection, metering, and communications, it reduces wiring complexity, accelerates commissioning, and lowers total cost of ownership across transformer assets.

Product Information

Extended Description

ETR-5000-2A1HA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A,1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz ,Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A1HA0
UPC
786679158128
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor Sensitive Ground Input URTD Interface
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Power Protection and Metering Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature: Eight digital inputs and nine outputs enable complex protection schemes with minimal external wiring. Benefit: Faster, more reliable fault isolation and reduced panel wiring, translating to shorter commissioning times and lower installation costs in substations and machine halls. Application: Transformer protection in industrial and utility environments where space is at a premium and precise I/O is required. Feature: Industry-standard communications: 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet RJ45. Benefit: Seamless integration with modern substation automation systems, improved interoperability, and centralized monitoring. Application: OEMs and utilities deploying interoperable protection and metering networks. Feature: Broad power-supply compatibility: 19-300 VDC and 40-250 VAC with 50/60 Hz operation. Benefit: Versatile deployment across diverse sites without auxiliary power rewiring or additional converters. Application: Retrofit projects and new builds where supply conditions vary. Feature: Advanced I/O options: IRIG-B Trip Coil Monitor, URTD Interface, and Sensitive Ground Input. Benefit: Precise timing, enhanced trip verification, and flexible grounding options improve system reliability. Application: Critical transformer protections in substations and heavy industrial plants. Feature: Removable terminals and semi-flush mounting. Benefit: Easier field maintenance, faster terminal rework, and cleaner panel layouts. Application: On-site servicing in confined spaces or retrofit installations. Feature: Built-in metering and protection capabilities with scalable I/O. Benefit: Consolidated device footprint, reduced panel count, and simpler asset management. Application: Modern transformer protection schemes requiring compact, scalable solutions.

Get a Quick Quote for a Eaton ETR-5000-2A1HA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A1HA0? Enquire Now

FAQs

The ETR-5000-2A1HA0 supports 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet, enabling seamless integration with modern substation automation and OEM monitoring systems for coordinated protection and diagnostics.
It provides 8 digital inputs and 9 outputs, with a power supply range of 19-300 VDC and 40-250 VAC and a frequency rating of 50/60 Hz, making it adaptable to varied site conditions and supply sources.
Yes, the device includes I/O options such as IRIG-B Trip Coil Monitor and URTD Interface, offering precise timing and extended monitoring capabilities for critical transformer protection schemes.
The ETR-5000-2A1HA0 uses removable terminals and semi-flush mounting, which simplifies field wiring and installation, especially in retrofit projects or tight panel spaces.
Ideal for transformer protection in substations and OEM equipment, it consolidates protection, metering, and communications in a single node, reducing wiring, accelerating commissioning, and delivering improved protection coordination and remote diagnostics.