The Eaton transformer relay ETR-5000-2A1HB1 provides robust transformer protection for power distribution and industrial automation networks. Engineers often struggle with reliable transformer monitoring and seamless integration across field protocols. Typical certifications for protective relays include CE, SIL, and IP-rated enclosures; verify exact listings on the official Eaton specification sheet. With Ethernet communications supporting 61850, Mbus TCP, and DNP3 TCP/UDP, this device offers flexible remote diagnostics and fast fault isolation. It also accepts a wide input range (19-300 VDC or 40-250 VAC) and provides 8 digital inputs, 9 outputs, plus 2 current sensing inputs, enabling scalable protection and metering. The result is improved uptime, easier compliance reporting, and streamlined maintenance for transformer protection in demanding industrial environments.

Product Information

Extended Description

ETR-5000-2A1HB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 40-250 Vac, 19-300 Vdc, 8, 9, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A1HB1
UPC
786679158272
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Trip Coil Monitor IRIG-B Sensitive Ground Input
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Power Protection and Metering Differential Protection Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Feature: 8 digital inputs and 9 outputs with 2 current sensing inputs. Benefit: Enables comprehensive protection schemes and metering while reducing external hardware needs. Application: Transformer protection and control in compact control panels. The 8/9 I/O set supports flexible logic and sequencing for fast fault isolation and reliable alarm signaling. Feature: Ethernet communication via 61850, Mbus TCP, and DNP3 TCP/UDP. Benefit: Seamless integration with modern substation and plant networks, enabling remote monitoring and centralized data analytics. Application: OEMs and utilities deploying enterprise-grade protection and diagnostics. Feature: Power supply range 19-300 VDC / 40-250 VAC and 50/60 Hz. Benefit: Universal compatibility simplifies installation across varied plant sites and reduces stock of power rails. Application: New builds and retrofits in mixed electrical environments. Feature: I/O options including URTD Interface, Trip Coil Monitor, IRIG-B, and Sensitive Ground Input. Benefit: Enhanced fault coordination, time synchronization, and signal fidelity for high-accuracy protection. Application: Critical transformer protection with precise timing and monitoring requirements. Feature: Conformal coating and rugged mechanical design with removable terminals and projection mounting. Benefit: Improved field reliability, easier installation, and maintenance in harsh environments. Application: Panel-mounted protection relays in OEM equipment and industrial power systems. Feature: Base relay compatibility with ETR-4000. Benefit: Streamlined migration paths and extended service life with proven platform architecture. Application: Upgrading legacy protection schemes without wholesale hardware changes.

Get a Quick Quote for a Eaton ETR-5000-2A1HB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A1HB1? Enquire Now

FAQs

The unit features removable terminals and projection mounting, which simplify panel-rack installation and field wiring. Plan for 8 digital inputs and 9 outputs, wire the power supply within 19-300 VDC or 40-250 VAC, and use the URTD interface or IRIG-B option for enhanced protection schemes. Proper grounding and secure mounting ensure reliable operation under industrial conditions.
ETR-5000-2A1HB1 supports 61850, Mbus TCP, and DNP3 TCP/UDP over Ethernet RJ-45. This enables straightforward integration with modern substations and plant networks, facilitating remote monitoring, data logging, and fast fault isolation without additional protocol gateways.
Yes. The device is designed for transformer protection and monitoring with 8 inputs, 9 outputs, 2 current sensing inputs, and a broad power supply range. Its conformal-coated boards and hardware compatibility with ETR-4000 provide a scalable path from protection to metering, suitable for OEMs and substations requiring robust protection with flexible integration.
Compliance details are provided by the manufacturer; the specification sheet and product documentation should list exact certifications. Inquiries should reference the Eaton ETR-5000-2A1HB1 datasheet for CE, IP, or SIL listings as applicable to your market. Always verify current certifications before procurement to ensure regulatory alignment.
The ETR-5000-2A1HB1 enables remote diagnostics and centralized monitoring via Ethernet, reducing onsite visits and mean time to repair. Its extended wiring options, time-synchronized data capability, and compatibility with existing ETR-4000-based systems support faster fault localization, improved uptime, and a lower total cost of ownership through streamlined maintenance and reporting.