Eaton ETR-5000-2A1KA0 Transformer Relay - 50/60 Hz
Part Number: ETR-5000-2A1KA0
Quick Summary
Eaton transformer relay protects transformers by monitoring voltages and faults for reliable power distribution. In critical bus and plant networks, a delayed fault response can cause downtime and equipment damage. Compliances vary by market; confirm CE/SIL/IP approvals with Eaton and reference the datasheet. This transformer protection relay integrates with Modbus/DNP3 TCP over fiber Ethernet and supports removable terminals, delivering measurable reliability and ROI.
Product Information
Extended Description
ETR-5000-2A1KA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9, Removable, Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz Sensitive Ground Input,Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A1KA0
UPC
786679158593
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Sensitive Ground Input IRIG-B Trip Coil Monitor
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Voltage Protection and Metering Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
E-series protective relays
E-series protective relays
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Eaton Specification Sheet - ETR-5000-2A1KA0
Feature → Business Impact → Application. The 8 digital inputs and 9 outputs enable complex interlocking and smart sequencing, reducing the risk of misoperation and enabling faster fault isolation in substations and industrial plants. This directly translates to improved uptime, lower repair costs, and easier compliance with zone selective interlocking strategies across feeders. Feature → Business Impact → Application. The wide power-supply range of 19-300 Vdc and 40-250 Vac supports diverse plant environments and reduces the need for multiple controllers, cutting spare-part inventories and enabling seamless integration with existing power architectures. Feature → Business Impact → Application. Removable terminals simplify field maintenance and relamping work, lowering downtime during wiring changes and facilitating rapid upgrades or replacements in retrofit projects. Feature → Business Impact → Application. Modbus and DNP3 TCP over LC duplex fiber Ethernet provide robust, long-distance communication with SCADA and historian systems, improving visibility, alarm management, and data-driven decision making in large facilities. Feature → Business Impact → Application. The I/O options including URTD Interface, Sensitive Ground Input, IRIG-B, and Trip Coil Monitor deliver advanced protection features such as precise ground fault detection and time-synced monitoring for coordinated protection schemes, boosting overall system reliability. Feature → Business Impact → Application. With 5 A/1 A phase current sensing and 50/60 Hz operation, the unit delivers accurate protection decisions across a range of transformer sizes, helping engineers tune protection curves for better selectivity and reduced nuisance trips.
Get a Quick Quote for a Eaton ETR-5000-2A1KA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2A1KA0?
Enquire Now
FAQs
The ETR-5000-2A1KA0 uses removable terminals to simplify installation and field replacement. Begin with de-energizing the circuit, mount the unit in the control cabinet, and connect power and I/O per the wiring diagram. The removable terminals allow quick wiring changes and streamlined maintenance, reducing setup time and minimizing commissioning risk in challenging environments.
This model features 8 digital inputs and 9 outputs, with a power-supply range of 19-300 Vdc and 40-250 Vac supporting 50/60 Hz operation. It includes phase current sensing options of 5 A and 1 A, and supports multiple protection functions such as voltage, current, and differential protection, enabling precise protection coordination.
Yes. The relay supports Modbus and DNP3 TCP communications over LC duplex fiber optic Ethernet, enabling robust integration with SCADA, HMIs, and historian systems. This facilitates remote monitoring, alarm management, and data-rich protection schemes across distributed transformer networks.
Compliances are provided by the manufacturer and vary by market. For the ETR-5000-2A1KA0, contact Eaton to confirm CE, SIL, IP, or other regional approvals applicable to your jurisdiction. Always refer to the Eaton datasheet and local regulatory requirements to ensure correct certification coverage for your installation.
The ETR-5000-2A1KA0 offers enhanced protection reliability, faster fault isolation, and scalable protection schemes, reducing unscheduled downtime and maintenance costs. Its removable terminals simplify maintenance, while fiber ethernet communication supports remote diagnostics. Eaton’s one-year warranty and the documented 25-000 policy provide a clear support and ROI framework throughout the installation lifecycle.