Eaton transformer relay ETR-5000-2A2BA0 - RS-485 Modbus

Part Number: ETR-5000-2A2BA0
Manufacturer
Eaton
Part number
ETR-5000-2A2BA0

Quick Summary

Eaton transformer relay provides transformer protection and remote monitoring for industrial power systems. It integrates with modern control networks, reducing setup time and minimizing misconfiguration during commissioning. A common pain point is wiring complexity and slow fault diagnosis across protection, metering, and trip logic. This model supports Modbus RTU or DNP3 RTU over RS-485, giving you robust SCADA integration while preserving local protection functions. Compliance details are listed as 'Contact Manufacturer'—verify CE, SIL, and IP ratings with Eaton for your regulatory needs. With 8 digital inputs, 9 digital outputs, 2 current sensing inputs, and a wide power range (19-300 Vdc, 40-250 Vac) it delivers reliable operation, fast fault isolation, and scalable protection for transformers.

Product Information

Extended Description

ETR-5000-2A2BA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil MonitorSensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A2BA0
UPC
786679158685
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Sensitive Ground Input Trip Coil Monitor IRIG-B
Modbus / DNP3 RTU
over RS-485
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Power Protection and Metering Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature: Modbus RTU or DNP3 RTU over RS-485 enables seamless integration with SCADA systems. Business Impact: Reduces commissioning time and enables remote diagnostics, lowering onsite visits. Application: Transformer protection relays in distribution networks and OEM equipment where reliable communication is critical. Feature: 8 digital inputs, 9 digital outputs, and 2 current sensing inputs provide comprehensive protection and metering. Business Impact: Consolidates protection logic, simplifies wiring, and supports zone selective interlocking for faster isolation. Application: Transformer protection and metering in substations and compact switchgear. Feature: Wide power supply range of 19-300 Vdc and 40-250 Vac with 50/60 Hz compatibility. Business Impact: Flexible installation across varying plant architectures, minimizing ancillary power components. Application: Dual-source environments and retrofit projects. Feature: Terminal configuration with removable terminals and semi-flush mounting enables quick field installation. Business Impact: Reduces commissioning time and maintenance costs, improving uptime. Application: OEM assemblies and retrofit installations where space and serviceability matter. Feature: I/O options like Trip Coil Monitor and IRIG-B support enhance fault detection and time synchronization. Business Impact: Improves protection accuracy and event logging for compliance audits. Application: Power protection and monitoring in critical facilities and industrial plants.

Get a Quick Quote for a Eaton ETR-5000-2A2BA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A2BA0? Enquire Now

FAQs

Yes. The relay offers 8 digital inputs, 9 digital outputs, 2 current sensing inputs, and removable terminals for easy field wiring. Its semi-flush mounting and voltage sensing inputs compatible with 19-300 Vdc and 40-250 Vac simplify integration into standard protection panels and OEM enclosures.
The unit supports Modbus RTU or DNP3 RTU over RS-485, enabling reliable SCADA connectivity and remote diagnostics. This reduces on-site visits, facilitates centralized monitoring, and improves fault tracing in transformer protection schemes.
Yes. The product supports zone selective interlocking (2 zones) and provides multiple protection and metering functions, including differential protection in its sensing and control capabilities, supporting fast, coordinated tripping in complex power networks.
The data indicates compliance details are listed as 'Contact Manufacturer.' For regulatory requirements such as CE, SIL, or IP ratings, contact Eaton directly to obtain the latest certification documentation and ensure the device meets your project’s standards.
Warranty is Eaton’s standard policy: one year from installation or eighteen months from shipment, whichever occurs first. This, combined with 8/9 I/O and robust RS-485 communications, supports long-term uptime and reduces maintenance costs through early fault detection and reliable protection.