Eaton ETR-5000-2A2BA1 Transformer Relay - Modbus RTU RS485

Part Number: ETR-5000-2A2BA1
Manufacturer
Eaton
Part number
ETR-5000-2A2BA1

Quick Summary

The Eaton transformer relay ETR-5000-2A2BA1 is designed to protect transformers and feeders in industrial facilities by monitoring voltages, currents, and faults. Users often struggle with slow fault isolation and limited remote diagnostics, leading to extended downtime. Certification details vary by region, and this listing notes Compliances as Contact Manufacturer; typical transformer relays in this class align with CE marking and robust IP protection depending on the install context, with SIL levels defined per application. With Modbus RTU over RS485 and flexible power inputs, this device supports scalable protection, easier integration into SCADA, and a stronger business case for reduced maintenance costs and improved system uptime.

Product Information

Extended Description

ETR-5000-2A2BA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, ProjectionSensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A2BA1
UPC
786679155646
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Trip Coil Monitor IRIG-B Sensitive Ground Input
Modbus / DNP3 RTU
over RS-485
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Power Protection and Metering Differential Protection Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Feature → Business Impact → Application: Communications and I/O. The ETR-5000-2A2BA1 provides Modbus RTU or DNP3 RTU over RS485, enabling seamless integration with existing SCADA and historian systems. This reduces field trips and accelerates fault isolation, improving transformer protection workflows across substations and industrial plants. Application: transformer protection relay in distribution networks and plant-wide protection schemes. Power range and compatibility. The unit supports a wide power input range of 19-300 VDC and 40-250 VAC at 50/60 Hz, simplifying installation across varied plant electrical environments and reducing wiring errors. Application: installations with mixed supply architectures and legacy equipment. Flexible I/O for advanced protection schemes. Eight digital inputs and nine digital outputs, plus two current-sensing inputs, enable zone selective interlocking, differential protection, and metering-based protection without external add-ons. Business impact: higher protection fidelity and faster clear/hold decisions. Application: protection schemes in transformer substations and motor feeders. Protection and metering capabilities. Sensing inputs cover Voltage Protection and Metering, Power Protection and Metering, Differential Protection, and Current Protection and Metering, supporting precise fault detection and revenue-grade monitoring. Application: accurate protection logic and energy accounting for transformer banks. Physical design and installation efficiency. Removable terminals and projection mounting simplify field wiring, servicing, and retrofit projects, reducing installation time and enabling straightforward maintenance. Application: retrofit projects and new builds requiring robust, serviceable protection relays. I/O options and timing synchronization. URTD Interface, Trip Coil Monitor, IRIG-B time reference, and Sensitive Ground Input options enhance safety, timing accuracy, and diagnostic capabilities, improving overall protection reliability in complex electrical rooms. Application: critical industrial protection with time-stamped diagnostics and enhanced fault tracing.

Get a Quick Quote for a Eaton ETR-5000-2A2BA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A2BA1? Enquire Now

FAQs

The ETR-5000-2A2BA1 uses removable terminals and projection mounting for straightforward wiring and retrofits. It supports Modbus RTU or DNP3 RTU over RS485, and includes eight digital inputs plus nine outputs with two current sensing inputs, enabling quick integration into existing SCADA architectures without extensive reconfiguration.
Key specs include a power supply range of 19-300V DC or 40-250V AC, 50/60 Hz operation, eight digital inputs, nine digital outputs, two current sensing inputs, and protection/metrology functions for voltage, power, differential, and current protection. Communication is available via Modbus RTU or DNP3 RTU over RS485.
Yes. The ETR-5000-2A2BA1 is designed as a transformer protection relay with metering and protection features suitable for transformer banks in distribution substations and industrial plants. Its RS485 communications and zone selective interlocking support reliable protection coordination and remote diagnostics.
Certifications for this model are listed as Compliances: Contact Manufacturer in the data set. Confirm CE, IP, or SIL requirements with Eaton for your region and application, as exact approvals can vary by market and installation specifics.
The unit carries Eaton’s one-year warranty from installation or 18 months from shipment, whichever occurs first. Remote monitoring, robust diagnostics, and modular I/O reduce field maintenance visits and downtime, contributing to a lower total cost of ownership and faster return on investment for critical transformer protection.