Eaton transformer relay ETR-5000-2A2DA0 enables precise transformer protection in industrial power systems. Engineers often struggle with reliable protection coordination and Diagnostics across mixed voltage levels, limited network visibility, and complex field wiring. Typical protections in the field rely on disparate devices; this unit consolidates sensing, metering, and trip logic in one package. While exact certifications vary by region, common protections in this class include CE, SIL, and IP-based considerations; confirm Eaton's current compliance for your installation. The solution offers a flexible power input range, extensive I/O, and Profibus-DP communication over fiber, accelerating commissioning and improving uptime across transformer assets and downstream feeders.
Product Information
Extended Description
ETR-5000-2A2DA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Profibus-DP , 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input,Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A2DA0
UPC
786679156100
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Profibus-DP over Fiber Optic ST
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input IRIG-B Trip Coil Monitor URTD Interface
Phase current
5A, 1A
PROFIBUS-DP
over fiber optic ST
Sensing inputs
Differential Protection Current Protection and Metering Voltage Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
E-series protective relays
E-series protective relays
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Eaton Specification Sheet - ETR-5000-2A2DA0
Power supply versatility is built in with a universal range of 19-300 Vdc and 40-250 Vac, operating at 50/60 Hz. This flexibility supports global installations and reduces the need for separate power conditioning, cutting project time and wiring faults. Application note: transformer protection in mixed-voltage plants benefits from simplified supply architecture, enabling faster commissioning and fewer stock-keeping units. I/O density and protective features deliver tangible outcomes: 8 digital inputs, 9 digital outputs, and 2 current sensing inputs enable differential protection, metering, and zone coordination. Business impact: streamlined wiring, faster fault isolation, and clearer protection schemes that reduce outage duration. Application: transformer protection and subsystem interlocks in substations and OEM equipment. Communications with PROFIBUS-DP over fiber optic ST provide robust, EMI-resistant networking. Impact: plant-wide integration with low communication latency, improved diagnostics, and easier remote configuration. Application: factory automation and power protection networks that demand deterministic communications. Mechanical and installation advantages include removable terminals and semi-flush mounting, plus compatibility with the ETR-4000 base. Impact: faster retrofits, lower installation risk, and fewer hardware changes when upgrading existing protection schemes. Application: retrofits in aging transformer protection systems or new installations in compact panels. Protection breadth includes differential protection, current and voltage protection with metering, power protection and metering, and optional I/O features like Sensitive Ground Input, IRIG-B, Trip Coil Monitor, URTD interface. Impact: comprehensive protection coverage with simpler configuration and reduced external devices. Warranty and service: Eaton's stated policy offers one year from installation or 18 months from shipment, whichever comes first.
Get a Quick Quote for a Eaton ETR-5000-2A2DA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2A2DA0?
Enquire Now
FAQs
This unit features removable terminals and semi-flush mounting, simplifying field wiring and retrofit projects. It is designed to work with the ETR-4000 base, allowing seamless upgrades in existing protection schemes while maintaining compact panel profiles and straightforward cable management.
Yes. The relay supports PROFIBUS-DP over Fiber Optic ST, enabling robust, noise-immune communication between protection devices and PLCs or SCADA systems, which improves diagnostics and reduces commissioning time in harsh plant environments.
Power supply range is 19-300 Vdc and 40-250 Vac with a 50/60 Hz frequency rating. It includes 8 digital inputs, 9 digital outputs, 2 current sensing inputs, and supports a phase current of 5A/1A, making it suitable for comprehensive transformer protection and metering.
Ideal for transformer protection in industrial substations, OEM transformer equipment, and large drive systems. Its integrated protection features, zone selective interlocking, and networked monitoring support fast fault isolation and improved system uptime.
Compliances are listed as Contact Manufacturer, and exact regional certifications should be confirmed with Eaton. The warranty follows Eaton's policy: 1 year from installation or 18 months from shipment, whichever occurs first, providing assurance for early-life reliability.