Eaton transformer relay ETR-5000-2A2FA1 - Modbus RTU over Fiber
Part Number: ETR-5000-2A2FA1
Quick Summary
Eaton transformer relay ETR-5000-2A2FA1 protects transformers in substations and industrial plants with integrated protection, metering, and remote communication. Engineers often struggle with coordinating protection across devices and maintaining secure, auditable remote diagnostics in harsh environments. Note that compliance details such as CE, SIL, and IP ratings should be confirmed with Eaton. This device provides robust transformer protection, precise timing, and flexible communication, supporting efficient maintenance and rapid fault isolation in power networks and equipment upgrades.
Product Information
Extended Description
ETR-5000-2A2FA1 Eaton: Eaton transformer relay, Modbus RTU or DNP3 RTU , 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input, IRIG-B, Trip Coil Monitor, URTD Interface, Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A2FA1
UPC
786679158807
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over Fiber Optic ST
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor Sensitive Ground Input URTD Interface
Modbus / DNP3 RTU
over fiber optic ST
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Voltage Protection and Metering Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
E-series protective relays
E-series protective relays
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Eaton Specification Sheet - ETR-5000-2A2FA1
Eaton ETR-5000-2A2FA1 is designed to fit a broad range of protection schemes while simplifying installation and maintenance. Feature → Business Impact → Application: Flexible power supply range of 19-300 Vdc and 40-250 Vac supports diverse plant architectures, reducing the need for multiple converters and enabling quicker retrofits in legacy substations. This translates to reduced capital expenditure and faster project delivery for transformer protection upgrades in manufacturing facilities and process plants. Feature → Business Impact → Application: Modbus RTU or DNP3 RTU communications over fiber optic ST delivers secure, interference-free remote monitoring and control, enabling centralized diagnostics and faster fault isolation across distributed energy assets in data centers and utility-scale installations. Feature → Business Impact → Application: 8 digital inputs, 9 digital outputs, and 2 current sensing inputs provide rich protection logic, metering, and control channels, which reduces external hardware count and accelerates commissioning in switchgear and transformer yards. Feature → Business Impact → Application: I/O options such as IRIG-B, Trip Coil Monitor, Sensitive Ground Input, and URTD Interface support precise time synchronization, fault detection, and advanced protection coordination, improving reliability in high-security environments like critical infrastructure facilities. Feature → Business Impact → Application: Removable terminals and projection mounting simplify installation and field servicing, enabling quicker replacements and safer upgrades in cramped or retrofit environments.
Get a Quick Quote for a Eaton ETR-5000-2A2FA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2A2FA1?
Enquire Now
FAQs
When installing the ETR-5000-2A2FA1, ensure power supplies within 19-300 Vdc or 40-250 Vac are available and that mounting is compatible with projection-based enclosures. Take advantage of removable terminals to simplify wiring, verify fiber optic ST connectivity for Modbus RTU or DNP3 RTU, and plan for IRIG-B and URTD interface integration during commissioning to streamline timing synchronization and fault monitoring.
Key specifications include the dual power supply range (19-300 Vdc, 40-250 Vac), 50/60 Hz operation, 8 digital inputs and 9 digital outputs, and 2 current sensing inputs (5A and 1A). Confirm compatibility with your transformer protection scheme, and ensure the communication path supports Modbus RTU or DNP3 RTU over fiber optic ST for secure remote diagnostics.
Yes. The ETR-5000-2A2FA1 is designed for transformer protection and metering in both substations and industrial facilities. Its integrated communications, time synchronization features, and flexible inputs/outputs support comprehensive protection schemes, fast fault isolation, and reliable monitoring across distributed power systems.
Compliances are listed as 'Contact Manufacturer' for this model, so confirm with Eaton or your distributor whether CE, SIL, IP ratings, or other local regulatory certifications apply to your installation. Always obtain the latest certification documentation to ensure regulatory alignment and safety requirements for your region.
The device offers a one-year warranty (or 18 months from shipment, per Eaton policy) and supports easy field servicing due to removable terminals and a robust fiber-based communication path. ROI benefits come from reduced wiring complexity, faster commissioning, centralized remote diagnostics, and improved transformer protection reliability, leading to lower mean time to repair (MTTR) and fewer unplanned outages.