Eaton Transformer Relay ETR-5000-2A2GA0 - Transformer protection relay

Part Number: ETR-5000-2A2GA0
Manufacturer
Eaton
Part number
ETR-5000-2A2GA0

Quick Summary

Eaton transformer relay protects transformer circuits in power distribution, delivering reliable monitoring and fault protection for industrial plants. Engineers often struggle with integrating protection, metering, and remote diagnostics across legacy control systems. Certification and compliance details vary by market, so verify CE, IP, and SIL status with Eaton before deployment. With Modbus RTU or DNP3 RTU over RS-485, and a rich I/O setup, the device supports scalable, maintainable protection strategies. This translates to faster fault isolation, reduced downtime, and simplified commissioning for OEMs and service providers.

Product Information

Extended Description

ETR-5000-2A2GA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, D-Sub / RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A2GA0
UPC
786679156735
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input Trip Coil Monitor URTD Interface IRIG-B
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Differential Protection Current Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Power and compatibility flexibility helps you install this relay across varied plant environments. The device supports a wide power supply range—19-300 Vdc and 40-250 Vac—and operates at both 50/60 Hz, reducing the need for multiple spares and simplifying retrofits in legacy installations. Its semi-flush mounting and removable terminals streamline wiring, test, and commissioning in confined panels. By consolidating protection, metering, and communication in one unit, you cut wiring complexity, shorten project timelines, and accelerate maintenance response. This makes it an ideal choice for transformer protection in OEM equipment and automation plants where uptime matters. Eight digital inputs, nine outputs, and two current-sensing inputs enable richer protection logic without external relays. Zone selective interlocking—2 zones—helps coordinate faults and isolate faults faster, improving safety and system reliability. The inclusion of Sensitive Ground Input, Trip Coil Monitor, URTD, and IRIG-B timing options gives precise protection coordination and time synchronization across distributed assets. Communication and interoperability is provided by Modbus RTU or DNP3 RTU over RS-485 with D-Sub field connections for robust signal integrity and SCADA/EMS integration. With built-in metering, protection, and remote diagnostics, operators gain visibility and control from a single interface, reducing field service visits and enabling proactive maintenance. Upgrade path and protection layers include base relay compatibility with the ETR-4000, offering a clear migration path for legacy installations and consistent protection logic across fleets. The product supports 50/60 Hz, voltage protection and metering, and configurable I/O for easier system upgrades and spare-part planning. Warranty and service terms support project risk management: Eaton’s 25-000 policy provides one year from installation or eighteen months from shipment, whichever occurs first, delivering predictable maintenance budgeting and reduced downtime.

Get a Quick Quote for a Eaton ETR-5000-2A2GA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A2GA0? Enquire Now

FAQs

The ETR-5000-2A2GA0 supports semi-flush mounting and removable terminals for easier wiring and testing in tight panel spaces. It is compatible with standard 19-inch enclosures and can be wired with readily available D-SUB/RS-485 connections for Modbus RTU or DNP3 RTU, enabling straightforward retrofits in legacy transformer protection setups.
Key specs include a power supply range of 19-300 Vdc and 40-250 Vac, 50/60 Hz operation, eight digital inputs, nine outputs, and two current sensing inputs. Communications are via Modbus RTU or DNP3 RTU over RS-485 (D-Sub connectors). It also supports base relay compatibility with ETR-4000 and features options like Sensitive Ground Input and URTD/IRIG-B timing.
Yes. The ETR-5000-2A2GA0 is designed for transformer protection in both substations and OEM equipment. Its 8/9 I/O configuration, zone selective interlocking capability, and RS-485 communication enable coordinated protection, metering, and remote diagnostics across distributed assets, making it suitable for complex protection schemes in industrial power systems.
Certification details are provided by the manufacturer and can vary by region. Customers should verify CE, IP ratings, and SIL status with Eaton for their specific market and application. Always confirm the exact regulatory certifications required by your project specification and local electrical codes before deployment.
The device carries Eaton’s warranty policy of 1 year from installation or 18 months from shipment. ROI benefits include reduced downtime through integrated protection and diagnostics, simplified commissioning, fewer external relays, and lower spare-parts inventory due to a single multi-function unit addressing protection, metering, and communication needs.