Eaton transformer relay ETR-5000-2A2GB0 - 50/60 Hz

Part Number: ETR-5000-2A2GB0
Manufacturer
Eaton
Part number
ETR-5000-2A2GB0

Quick Summary

Eaton transformer relay protects transformers and circuits in industrial power systems. Engineers often struggle with coordinating protection logic, communications, and diagnostics across dispersed assets, leading to slower fault isolation. Typical certifications for this class include CE compliance, IP ratings, and SIL considerations; verify exact markings on Eaton’s official datasheets. By deploying this device, teams gain reliable transformer protection, flexible Modbus RTU or DNP3 RTU communications over RS-485, and scalable metering integration for plant-wide visibility. The result is faster fault isolation, improved SCADA integration, and reduced downtime costs, all while supporting future digital upgrades and cross-site standardization.

Product Information

Extended Description

ETR-5000-2A2GB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A2GB0
UPC
786679156759
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Sensitive Ground Input Trip Coil Monitor URTD Interface
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Voltage Protection and Metering Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature: 8 digital inputs and 9 digital outputs paired with Modbus RTU or DNP3 RTU over RS-485 enables comprehensive protection logic and remote monitoring. Business impact: This architecture supports precise event-driven trips, meaningful diagnostics, and easy integration with existing control systems, shortening fault response times. Application: Transformer protection in manufacturing floors and utility-like plant environments. Feature: Wide power supply range of 19-300 Vdc and 40-250 Vac, plus 50/60 Hz operation, ensures compatibility across global sites. Business impact: Reduces the need for multiple variants and simplifies procurement, saving engineering time and stock holding. Application: Global installations in data centers, petrochemical, and processing facilities. Feature: Removable terminals and semi-flush mounting simplify panel retrofits and field upgrades. Business impact: Speeds installation, minimizes downtime, and improves reliability in confined spaces. Application: Retrofit projects in existing switchgear and control panels. Feature: Conformal coated circuit boards and rugged construction protect against challenging environments. Business impact: Increases uptime by resisting moisture, dust, and corrosive atmospheres, reducing maintenance costs. Application: Factory floors, substations, and outdoor installations. Feature: Flexible I/O options, including IRIG-B, Sensitive Ground Input, Trip Coil Monitor, and URTD Interface, enable precise protection schemes and time synchronization. Business impact: Improves protection coordination and data accuracy for DCS and SCADA. Application: Power systems requiring tight interlock and event timing in electric utilities or large industrial plants. Feature: Modbus / DNP3 RTU over RS-485, 5A/1A current sensing inputs, and zone selective interlocking support advanced protection. Business impact: Enhances interoperability with third-party devices and lowers integration risk. Application: Complex protection schemes in multi-transformer facilities.

Get a Quick Quote for a Eaton ETR-5000-2A2GB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A2GB0? Enquire Now

FAQs

Consider panel space for the semi-flush mounting and the removable terminals to simplify wiring during retrofit. Plan for a 19-300 Vdc or 40-250 Vac power supply and 50/60 Hz operation. Ensure RS-485 network availability for Modbus RTU or DNP3 RTU communications and verify grounding and interlock configurations before commissioning.
It combines 8 digital inputs with 9 outputs, flexible Modbus RTU/DNP3 RTU over RS-485, and IRIG-B/Sensitive Ground Input options, enabling precise protection schemes, fast fault isolation, and robust monitoring. This makes it well-suited for complex transformer protection in manufacturing, data centers, and energy-intensive facilities.
Yes. The relay communicates over RS-485 via Modbus RTU or DNP3 RTU, allowing seamless integration with existing SCADA and DCS platforms. This standard interface supports remote monitoring, event logging, and coordinated protection actions across multi-device networks.
Compliance details are provided by the manufacturer; check Eaton’s official datasheets and the E-Series protective relays documents for CE, IP, SIL, and related certifications where applicable. Always verify the exact markings on the latest Eaton specification sheets before procurement and installation.
The device carries Eaton’s warranty policy of one year from installation or eighteen months from shipment, whichever occurs first. This warranty, combined with improved fault isolation, reduced downtime, and SCADA-ready integration, contributes to lower operational risk and faster return on investment in transformer protection deployments.