Eaton ETR-5000-2A2HA0 Transformer Relay - 61850 TCP/UDP

Part Number: ETR-5000-2A2HA0
Manufacturer
Eaton
Part number
ETR-5000-2A2HA0

Quick Summary

Eaton transformer relay ETR-5000-2A2HA0 provides transformer protection for industrial power systems. Engineers often struggle with integrating diverse communication protocols and scalable protection features in tight installations. Verify certifications such as CE, SIL, and IP ratings with Eaton for this model to ensure compliance and rugged operation in harsh environments. The device supports 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet, enabling seamless SCADA integration and diagnostics. With eight digital inputs, nine outputs, and a wide power-supply range (19-300 Vdc, 40-250 Vac), it streamlines installation and future upgrades. This combination delivers reliable transformer protection while reducing downtime and increasing asset uptime.

Product Information

Extended Description

ETR-5000-2A2HA0 Eaton: Eaton, transformer relay, ETR-4k, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A2HA0
UPC
786679156933
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Trip Coil Monitor IRIG-B Sensitive Ground Input
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
The ETR-5000-2A2HA0 offers robust Ethernet-based protection with IEC 61850, M-Bus TCP, and DNP3 TCP/UDP communications, which translates to faster engineering, simplified integration with modern SCADA, and reduced commissioning time for transformer protection relays in substations and OEM equipment. This protocol versatility supports scalable protection schemes and centralized diagnostics, enabling proactive maintenance and improved asset visibility. The 8 digital inputs and 9 outputs, coupled with 2 current sensing inputs, provide flexible protection logic and metering capabilities, supporting advanced protection schemes and accurate fault discrimination in demanding environments. Wide power supply coverage (19-300 Vdc, 40-250 Vac) enables global deployment without multiple power configurations, lowering installation costs and simplifying spare-part planning. Removable terminals and semi-flush mounting streamline field wiring and future upgrades, reducing downtime during maintenance windows and enabling repeatable, fault-tolerant installations. Zone selective interlocking (2) enhances system reliability by enabling fast, coordinated fault isolation across feeder sections, lowering outage impact and improving safety margins for critical transformer assets. IRIG-B, URTD Interface options, and sensitive ground input support provide additional interoperability and protection options for complex automation architectures in power distribution and industrial plants.

Get a Quick Quote for a Eaton ETR-5000-2A2HA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A2HA0? Enquire Now

FAQs

Plan for eight digital inputs and nine outputs, plus two current sensing inputs. Choose a semi-flush mounting with removable terminals to simplify wiring and future maintenance. Ensure your enclosure provides adequate space for the Ethernet cabling and URTD or IRIG-B option modules if used. Verify that the power supply range (19-300 Vdc, 40-250 Vac) matches your site conditions.
It enables fast fault isolation through zone selective interlocking and supports centralized diagnostics via Ethernet-based protocols like 61850, M-Bus TCP, and DNP3 TCP/UDP. The 8/9 I/O configuration supports versatile protection logic and metering, while the wide power range supports reliable operation across global sites, reducing downtime and maintenance costs.
Yes. The relay provides communication options including IEC 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet RJ45, enabling seamless integration with modern substation and industrial automation networks. Ensure firmware and commissioning tools are updated to the supported protocol versions for optimal performance.
Key specs include power supply range of 19-300 Vdc and 40-250 Vac, frequency rating of 50/60 Hz, eight digital inputs, nine outputs, two current sensing inputs, and removable terminals with semi-flush mounting. The device supports zone selective interlocking (2) and has a 5A/1A phase current range, suitable for protective relay applications.
Official documentation is available from Eaton, including the ETR-5000-2A2HA0 specification sheet and OEM brochures. Access the Eaton product page and downloads section to obtain the PDF datasheet, installation guidelines, and application notes to ensure proper integration, compliance, and maintenance planning.