Eaton transformer relay securely protects transformer systems in substations and industrial plants. Engineers often struggle with fast fault isolation and reliable remote monitoring across distributed networks. Note: Compliances are listed as 'Contact Manufacturer' on the datasheet, so confirm certifications such as CE, SIL, or IP ratings with Eaton for your region. The device supports Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Enet, eight digital inputs, nine outputs, and a wide power range, enabling flexible deployment and real-time asset management. This translates into reduced downtime and improved lifecycle management for critical transformer assets.

Product Information

Extended Description

ETR-5000-2A2LA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A2LA0
UPC
786679157596
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor Sensitive Ground Input URTD Interface IRIG-B
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Differential Protection Current Protection and Metering Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
The ETR-5000-2A2LA0 features removable terminals and semi-flush mounting, enabling faster field installation and easier retrofits in tight panels; this reduces commissioning time and wiring costs while improving reliability. With eight digital inputs and nine outputs plus diverse I/O options such as Trip Coil Monitor, Sensitive Ground Input, URTD Interface, and IRIG-B, operators gain granular control and precise protection coordination, lowering risk and improving fault containment. The power supply range of 19-300 Vdc and 40-250 Vac, combined with 50/60 Hz compatibility, supports operation across geographies and varying electrical systems, reducing spare parts and stocking requirements. Mbus TCP or DNP3 over LC duplex fiber enables robust SCADA integration, enabling proactive maintenance, remote diagnostics, and centralized fault analytics. Zone selective interlocking (2) further enhances selective tripping, delivering faster restoration and reduced outage impact for utilities and OEMs. Overall, the solution offers a scalable path to digital transformer protection, improving compliance, efficiency, and total cost of ownership.

Get a Quick Quote for a Eaton ETR-5000-2A2LA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A2LA0? Enquire Now

FAQs

Plan for removable terminals and semi-flush mounting to simplify field wiring and maintenance. The device supports standard transformer protection architectures with eight digital inputs and nine outputs, enabling straightforward panel integration and easy retrofits. Ensure power supply compatibility within the 19-300 Vdc / 40-250 Vac range and verify network cabling for Mbus TCP or DNP3 over LC fiber.
It provides differential protection, current protection and metering, power protection and metering, and voltage protection and metering through sensing inputs. With 2 current sensing inputs and 8 digital inputs, you can configure precise protection schemes and metering across multiple transformer assets, supported by Zone Selective Interlocking for coordinated tripping and minimized outage impact.
The relay supports Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet, enabling reliable, low-latency data exchange with SCADA and OT networks. This makes remote monitoring, diagnostics, and asset health trending feasible across dispersed substations and industrial facilities, reducing现场现场现场 downtime and enabling proactive maintenance scheduling.
Key resources include the Eaton specification sheet for the ETR-5000-2A2LA0 and brochures on E-Series protective relays. The downloads section also offers multimedia content on interfacing with E-Series Relays and a range of datasheets. Use these documents to guide wiring, configuration, and integration with power management and monitoring systems.
Warranty is governed by Eaton's policy 25-000: one year from installation or eighteen months from shipment, whichever occurs first. For compliance questions, configurator support, or regional certification details (CE, SIL, IP), contact Eaton directly or your authorized distributor to confirm applicable terms and service options.