Eaton ETR-5000-2A2LA1 Transformer relay - 19-300/40-250V

Part Number: ETR-5000-2A2LA1
Manufacturer
Eaton
Part number
ETR-5000-2A2LA1

Quick Summary

Eaton transformer relay provides protection and metering for transformer systems across OEM and substation applications. Engineers often struggle to coordinate protection schemes while integrating legacy relays with modern SCADA and fiber networks. Public data lists compliance only as 'Contact Manufacturer'; verify CE, SIL, IP ratings directly with Eaton. By supporting Mbus TCP and DNP3 TCP/UDP over LC duplex fiber Ethernet, it enables scalable monitoring and faster outage response. With 8 digital inputs, 9 outputs, and 2 current sensing inputs, the unit delivers flexible protection and metering for transformer assets across evolving industrial installations.

Product Information

Extended Description

ETR-5000-2A2LA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection, Sensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A2LA1
UPC
786679157619
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor URTD Interface Sensitive Ground Input
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection Voltage Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
The 8 digital inputs and 9 outputs provide versatile I/O for protection logic and remote signaling, reducing wiring complexity and enabling quicker fault isolation, which translates to lower downtime and safer equipment operation. In practice, the business impact is clearer protection coordination and faster diagnostic feedback, especially in substations or OEM equipment where space is at a premium and wiring runs are lengthy. The ability to communicate over Mbus TCP or DNP3 TCP/UDP via LC duplex fiber Ethernet directly supports SCADA integration, lowering total cost of ownership by simplifying remote monitoring, improving maintenance planning, and reducing on-site visits. The 2 current sensing inputs, along with configurable phase current options of 5A and 1A, enable precise metering and protection relays aligned with transformer loads and power quality needs. Power supply flexibility—19-300Vdc and 40-250Vac at 50/60 Hz—ensures compatibility across diverse site conditions, while removable terminals and projection mounting streamline installation and field service. I/O options such as IRIG-B, Trip Coil Monitor, URTD Interface, and Sensitive Ground Input extend protection coverage for critical assets. While compliance data requires direct confirmation from Eaton, the system’s modular inputs and robust fiber communications support scalable protection architectures, reducing future upgrade costs and enabling phased asset modernization. These features collectively support reliable transformer protection and diagnostic insights in complex multi-feed environments.

Get a Quick Quote for a Eaton ETR-5000-2A2LA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A2LA1? Enquire Now

FAQs

Installation is straightforward with removable terminals and projection mounting. Plan for 8 digital inputs and 9 outputs routing, keep power and communication cables organized, and follow the maximum voltage and current ratings listed in the spec sheet. For easier commissioning, use the URTD interface and verify fiber optic Mbus TCP / DNP3 TCP/UDP connectivity to your SCADA system.
The device provides 8 digital inputs, 9 digital outputs, and 2 current sensing inputs, enabling diverse protection logic, metering, and signaling. Phase current options are 5A and 1A, supporting multiple protection schemes. These I/O capabilities reduce external wiring, streamline relay logic, and allow coordinated trips and fault signaling across transformer assets.
Yes. It supports Modbus and DNP3 TCP communications over LC duplex fiber optic Ethernet, enabling seamless integration with modern SCADA and energy management systems while maintaining reliable remote monitoring.
Public data lists compliance as 'Contact Manufacturer' rather than specifying CE, SIL, or IP ratings. To ensure regulatory alignment for your project, contact Eaton directly to confirm current certifications and any country-specific approvals before deployment.
Eaton’s policy 25-000 provides a one-year warranty from installation or 18 months from shipment, whichever occurs first. For ongoing support, the Eaton specification sheet and support resources offer detailed guidance on configuration, diagnostics, and firmware updates to maximize asset uptime.