Eaton ETR-5000-2A2LB1 Transformer Relay - Mbus/DNP3 Enet

Part Number: ETR-5000-2A2LB1
Manufacturer
Eaton
Part number
ETR-5000-2A2LB1

Quick Summary

An Eaton transformer relay protects and monitors transformers in industrial power distribution, enabling fast fault detection. Engineers often wrestle with missed faults and slow restoration, risking equipment damage and downtime. Certification details are provided by the manufacturer; confirm CE, SIL, and IP ratings with Eaton to ensure regulatory alignment and site compliance. This model supports Mbus TCP or DNP3 TCP/UDP over LC duplex fiber optic Enet for secure remote communication and telemetry. With 8 digital inputs and 9 outputs, plus the base ETR-4000 platform, it offers flexible protection schemes and scalable diagnostics. The unit operates across 50/60 Hz and accepts 19-300 Vdc or 40-250 Vac, supporting mixed-plant environments and easy retrofits.

Product Information

Extended Description

ETR-5000-2A2LB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A2LB1
UPC
786679157817
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Sensitive Ground Input Trip Coil Monitor IRIG-B
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Differential Protection Current Protection and Metering Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Eight digital inputs and nine outputs provide on-board protection logic, reducing external wiring and cutting trip decision time. This consolidation improves fault isolation and system stability, essential in high-energy transformer protection schemes. In new builds or retrofit projects, the compact I/O set simplifies panel design and minimizes enclosure space, delivering a faster path to compliant protection and metering. Communication is provided via Mbus TCP or DNP3 TCP/UDP over LC duplex fiber optic Ethernet, delivering robust, low-latency data exchange. This enables secure remote monitoring, event logging, and seamless SCADA integration, reducing on-site visits and accelerating fault analysis. For greenfield or brownfield projects, the long-haul fiber option supports distributed assets without compromising performance. Wide power-supply range supports diverse plant electrification: 19–300 Vdc or 40–250 Vac, with a 50/60 Hz frequency rating. That means fewer card changes when migrating between industrial networks or upgrading equipment, lowering commissioning risk. The flexible supply also simplifies spare-part inventories and procurement, improving uptime during transitions. Conformal coating protects circuitry in challenging environments, extending service life in outdoor, damp, or dusty installations. The I/O options—URTD interface, Sensitive Ground Input, Trip Coil Monitor, IRIG-B—provide expanded protection logic and precise trip coordination for complex protection schemes. Designed as an evolution of the ETR-4000 base relay, the unit preserves familiar protection logic while expanding inputs, outputs, and diagnostics. Removable terminals and a projection mounting method simplify installation, testing, and field maintenance, enabling faster turnarounds during maintenance windows.

Get a Quick Quote for a Eaton ETR-5000-2A2LB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A2LB1? Enquire Now

FAQs

The ETR-5000-2A2LB1 builds on the ETR-4000 platform, preserving core protection logic while expanding I/O and communications. Retrofit can leverage existing protection schemes, easing migration and reducing design change risk.
The unit provides 8 digital inputs, 9 digital outputs, and 2 current sensing inputs, with a 50/60 Hz operating range and a power supply range of 19-300 Vdc or 40-250 Vac, enabling flexible integration into mixed-voltage installations.
Yes. The ETR-5000-2A2LB1 is designed for 50/60 Hz power systems and supports broad voltage inputs, making it suitable for transformer protection duties in substations and industrial networks.
Certification details are provided by the manufacturer; contact Eaton to confirm CE, SIL, IP ratings, and other regulatory certifications for your installation site.
On-board diagnostics, remote monitoring via Mbus/DNP3 over fiber, and expanded I/O reduce field visits, improve fault analysis, and shorten mean time to repair, supporting a lower total cost of ownership.