Eaton ETR-5000-2A3CB0 Transformer Relay - 40-250Vac
Part Number: ETR-5000-2A3CB0
Quick Summary
Eaton transformer relay ETR-5000-2A3CB0 provides transformer protection and metering for industrial power systems, substations, and big-motor facilities. Engineers often face challenges with protecting critical feeders, integrating protection layers, and achieving fast fault isolation across Ethernet-connected devices. Certification specifics such as CE marking, SIL readiness, IP ratings, and compatibility with industry standards should be confirmed with Eaton to meet your project requirements. This device supports Modbus TCP or DNP3 TCP/UDP over Ethernet RJ-45, URTD interface, and IRIG-B, enabling robust, scalable transformer protection with clear diagnostics and timing accuracy for modern networks.
Product Information
Extended Description
ETR-5000-2A3CB0 Eaton: Eaton transformer relay, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input, Trip Coil Monitor, IRIG-B, Sensitive Ground Input, URTD Interface
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A3CB0
UPC
786679157978
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor URTD Interface IRIG-B Sensitive Ground Input
Modbus / DNP3 RTU
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Differential Protection Current Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Specification Sheet - ETR-5000-2A3CB0
Feature: 8 digital inputs and 9 digital outputs enable rich I/O for local diagnostics and interlocking logic. Business Impact: reduces wiring complexity and speeds fault signaling to the control system, lowering MTTR. Application: deploy in transformer enclosures and switchgear where precise I/O mapping and zone selective interlocking are required. Feature: 2 current sensing inputs provide accurate overcurrent protection and metering data. Business Impact: improves protection accuracy and enables detailed energy monitoring for demand analysis. Application: substations and process plants with stringent protection curves. Feature: Wide power supply range 19–300 Vdc / 40–250 Vac and 50/60 Hz compatibility. Business Impact: simplifies installation across varied plant power rails, reducing customization time. Application: retrofits and greenfield projects with diverse electrical environments. Feature: Modbus TCP or DNP3 TCP/UDP over Ethernet RJ-45 plus URTD Interface and IRIG-B timing. Business Impact: scalable SCADA integration, synchronized diagnostics, and precise timing for coordinated protections. Application: modern industrial networks and utility-scale deployments. Feature: Conformal coated circuit boards, removable terminals, and semi-flush mounting. Business Impact: enhances reliability in harsh environments and simplifies field installation and maintenance. Application: rugged installations near feeders and outdoor substations. Feature: Base relay compatibility with ETR-4000 family. Business Impact: simplifies multi-relay integration and standardizes maintenance across protection schemes. Application: upgrade paths and modular protection architectures for existing Eaton systems.
Get a Quick Quote for a Eaton ETR-5000-2A3CB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2A3CB0?
Enquire Now
FAQs
Plan for seamless upgrade by verifying mounting method (semi-flush) and removable terminals. The ETR-5000-2A3CB0 is designed to be compatible with the ETR-4000 base relay family, enabling commonality in wiring and a single maintenance routine. Ensure correct I/O mapping (8 DI, 9 DO) and confirm the network interface (Ethernet RJ-45) for Modbus TCP or DNP3 networking.
Key specs include 8 digital inputs, 9 digital outputs, 2 current sensing inputs, power supply range from 19–300 Vdc or 40–250 Vac, and a 50/60 Hz frequency rating. Communication is via Modbus TCP or DNP3 TCP/UDP over Ethernet RJ-45, with URTD Interface and IRIG-B timing support for synchronized protection.
Yes. It’s designed as a transformer protection relay with metering capabilities, supports zone selective interlocking (2), and offers robust communications for SCADA integration via Modbus TCP or DNP3. Its rugged input/output configuration and timing features make it appropriate for substation protection schemes and reliable fault isolation.
Certification details are not listed in the provided data. Confirm CE marking, SIL readiness, IP ratings, and other project-specific certifications directly with Eaton to ensure alignment with your regulatory and safety requirements.
Warranty follows Eaton policy 25-000: one year from installation or eighteen months from shipment, whichever occurs first. Regular maintenance is typically focused on connector integrity and Ethernet communications; schedule periodic checks of IO status, timing accuracy (IRIG-B), and relay health to maintain protection reliability and minimize downtime.