Eaton ETR-5000-2A3EA1 Transformer Relay - Profibus-DP RS485

Part Number: ETR-5000-2A3EA1
Manufacturer
Eaton
Part number
ETR-5000-2A3EA1

Quick Summary

Eaton transformer relay is a robust protection device designed for transformer protection and metering in industrial power systems. Engineers often struggle with integrating protection relays into automation networks while maintaining clear diagnostics and fast fault isolation. While exact certifications aren’t listed here, transformer protection relays in this class typically pursue industry-standard compliances such as CE marking, IP enclosure protection, and SIL compatibility—verify with Eaton for this model. This product delivers reliable transformer protection and metering with advanced Profibus-DP communications, supporting efficient protection schemes and scalable automation. The Eaton solution also integrates seamlessly with OEM control architectures, offering value through improved reliability, diagnostics, and network compatibility in your power systems.

Product Information

Extended Description

ETR-5000-2A3EA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Profibus-DP over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over D-Sub/RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A3EA1
UPC
786679158579
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Profibus-DP over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input Trip Coil Monitor URTD Interface IRIG-B
Phase current
5A, 1A
PROFIBUS-DP
over D-Sub / RS-485
Sensing inputs
Current Protection and Metering Power Protection and Metering Differential Protection Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Feature → Business Impact → Application: 8 digital inputs and 9 digital outputs enable comprehensive protection logic and remote signaling, reducing controller complexity and enabling faster fault isolation in substations and on-the-fly diagnostics for plant-wide protection schemes. This translates to improved system uptime and easier integration with PLCs over Profibus-DP over RS-485 for rugged industrial networks. Feature → Business Impact → Application: 2 current sensing inputs plus 1 voltage sensing input support multi-parameter protection (current, voltage, differential) and metering, delivering accurate fault detection and energy monitoring for transformer banks in OEM equipment and centralized substations. Feature → Business Impact → Application: Power supply range of 19-300 VDC and 40-250 VAC with 50/60 Hz, plus removable terminals and projection mounting, simplify field installation, reduce commissioning time, and enable flexible panel layouts in new builds or retrofits. Feature → Business Impact → Application: I/O options including Sensitive Ground Input, Trip Coil Monitor, URTD Interface, and IRIG-B provide extended interoperability with protective schemes, trip coordination, and time synchronization—minimizing misoperations in high-stakes protection tasks. Feature → Business Impact → Application: Base relay compatibility with ETR-4000, Zone Selective Interlocking (2 zones), and 8/9 I/O count supports scalable protection architecture, lowering total cost of ownership by reusing a common platform across multiple transformer configurations. Feature → Business Impact → Application: Profibus-DP over D-Sub/RS-485 communications ensures robust, standards-based integration with enterprise and automation networks, enabling centralized diagnostics, event logging, and unified maintenance procedures across plants.

Get a Quick Quote for a Eaton ETR-5000-2A3EA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A3EA1? Enquire Now

FAQs

Install the relay using projection mounting with removable terminals for easy maintenance. Ensure the supply is within 19-300 VDC or 40-250 VAC and configure the Profibus-DP interface over RS-485 to the host PLC or SCADA. Follow the Eaton installation guide and verify wiring integrity before energizing the system.
The unit includes eight digital inputs and nine digital outputs, plus two current sensing inputs and one voltage sensing input. It also offers I/O options such as Sensitive Ground Input, Trip Coil Monitor, URTD Interface, and IRIG-B to support complex protection schemes and time synchronization in protection coordination.
Yes. It supports voltage protection and metering, current protection and metering, and differential protection. With Zone Selective Interlocking (two zones) and Profibus-DP communications, it enables fast fault isolation, precise metering, and scalable protection suitable for substations and OEM equipment.
The data indicates Compliance requires confirmation from the manufacturer. In practice, verify CE marking, IP enclosure protection, and SIL compatibility with Eaton for this specific model and your application to ensure regulatory alignment.
Eaton provides a warranty per policy 25-000: one year from installation or eighteen months from shipment, whichever occurs first. For service, plan preventive diagnostics and replacement parts as part of standard maintenance to maximize transformer protection reliability.