Eaton ETR-5000-2A3EB0 Transformer Relay - Profibus-DP

Part Number: ETR-5000-2A3EB0
Manufacturer
Eaton
Part number
ETR-5000-2A3EB0

Quick Summary

Eaton transformer relay ETR-5000-2A3EB0 protects transformer-based power systems in industrial automation. Engineers often battle nuisance trips and slow fault diagnosis when protection isn't tightly integrated with sensing and communications. As a transformer-protection relay, it supports Profibus-DP over D-SUB/RS-485 and wide voltage ranges to simplify panel design. Compliance details are provided by the manufacturer; verify CE marking, IP protection, or SIL credentials with Eaton for regulated environments. In short, it combines robust transformer protection, flexible I/O, and field-validated communication to support reliable, compliant operation. Its 8 digital inputs and 9 outputs, along with configurable protection logic, streamline engineering workflows and maintenance planning. The unit's conformal-coated circuit boards and removable terminals ease installation in harsh environments.

Product Information

Extended Description

ETR-5000-2A3EB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Profibus-DP over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz ,Sensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A3EB0
UPC
786679158319
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Profibus-DP over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface IRIG-B Trip Coil Monitor Sensitive Ground Input
Phase current
5A, 1A
PROFIBUS-DP
over D-Sub / RS-485
Sensing inputs
Power Protection and Metering Voltage Protection and Metering Differential Protection Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature -> Business Impact -> Application: The ETR-5000-2A3EB0 offers eight digital inputs and nine outputs, enabling centralized protection logic and easy integration with PLCs for faster fault isolation in transformer bays and substations. This translates to reduced downtime and improved safety in data centers and manufacturing plants. Feature -> Business Impact -> Application: Profibus-DP over D-SUB/RS-485 provides seamless remote monitoring and control, cutting integration time with existing SCADA systems and lowering commissioning costs across large automation projects. Feature -> Business Impact -> Application: A wide power supply range (19-300VDC, 40-250VAC) and 50/60 Hz compatibility support flexible installation in varied environments, simplifying panel design and ensuring consistent protection during voltage fluctuations. Feature -> Business Impact -> Application: Two current sensing inputs and explicit zone selective interlocking (2) improve selectivity, enabling precise fault localization and preventing collateral trips in multi-transformer installations. Feature -> Business Impact -> Application: Conformal coating, removable terminals, and URTD Interface / IRIG-B Trip Coil Monitor options reduce field maintenance time and improve reliability in harsh environments, from outdoor substations to indoor control rooms. Feature -> Business Impact -> Application: With 8 inputs and 9 outputs, plus 5A/1A phase current options, engineers gain flexible I/O configurations for metering, differential protection, and transformer monitoring, supporting compliance and operational efficiency in power distribution and process industries.

Get a Quick Quote for a Eaton ETR-5000-2A3EB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A3EB0? Enquire Now

FAQs

Yes. The ETR-5000-2A3EB0 supports Profibus-DP over D-SUB / RS-485 for easy integration with existing PLCs and SCADA systems. It features removable terminals for straightforward field wiring, semi-flush mounting, and a 19-300Vdc / 40-250Vac power range to fit diverse panel designs without major rewiring.
Key specs include 8 digital inputs, 9 outputs, 2 current sensing inputs, and a 50/60 Hz frequency rating. The device accepts 19-300Vdc or 40-250Vac supply and provides 5A / 1A phase current sensing, with a zone selective interlocking capability of 2. This combination supports precise, fast transformer protection and selective coordination.
Ideal for transformer protection in electrical distribution and industrial automation applications such as substations, data centers, and manufacturing plants. Its Profibus-DP communication, configurable I/O, and protection features support reliable transformer protection, monitoring, and remote diagnostics in centralized control architectures.
The product lists 'Compliances: Contact Manufacturer', so verify regulatory credentials with Eaton for your project. Typical deployments in regulated environments commonly require CE marking and appropriate IP-rated enclosures; confirm exact SIL/CIP requirements and enclosure ratings with Eaton to ensure compliance in your facility.
Warranty follows Eaton Selling Policy 25-000: one year from installation or 18 months from shipment, whichever occurs first. The device’s rugged construction, conformal-coated boards, and removable terminals reduce maintenance time and extend field service intervals, contributing to lower total cost of ownership for transformer protection schemes.