Eaton ETR-5000-2A3FA0 Transformer Relay - Modbus RTU over Fiber
Part Number: ETR-5000-2A3FA0
Quick Summary
The Eaton transformer relay ETR-5000-2A3FA0 protects transformers by monitoring voltage, current, and protection logic in industrial power systems. Engineers often struggle with missed fault signals and slow trips when integrating multiple protection layers. While exact certifications vary, transformer protection devices commonly align with SIL, CE, and IP-based standards; verify Eaton's datasheet for the ETR-5000-2A3FA0. With Modbus RTU or DNP3 RTU over fiber and a broad input range, this relay streamlines SCADA integration and simplifies maintenance, delivering improved reliability, faster fault isolation, and safer plant operation.
Product Information
Extended Description
ETR-5000-2A3FA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU , 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9, Removable, Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A3FA0
UPC
786679158326
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over Fiber Optic ST
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input URTD Interface Trip Coil Monitor IRIG-B
Modbus / DNP3 RTU
over fiber optic ST
Phase current
5A, 1A
Sensing inputs
Differential Protection Voltage Protection and Metering Current Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
E-series protective relays
E-series protective relays
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Eaton Specification Sheet - ETR-5000-2A3FA0
Selling Policy 25-000 - Distribution and Control Products and Services
Feature: Eight digital inputs and nine outputs provide rich local I/O for protection logic, trip commands, and interlocking. Business Impact: Reduces external relays, trims wiring, and speeds installation in new and retrofit projects. Application: Transformer protection schemes in substations and plant substations benefit from compact, integrated control. Feature: Modbus RTU or DNP3 RTU over fiber optic ST enables secure, high-integrity communications with SCADA systems. Business Impact: Simplifies remote monitoring, reduces communication-related downtime, and improves event logging. Application: Ideal for transformer protection with centralized control and diagnostics. Feature: Wide power supply range from 19-300 Vdc and 40-250 Vac with 50/60 Hz operation. Business Impact: Flexible integration across diverse plant power rails without extra power supplies. Application: Suitable for retrofits and greenfield projects alike. Feature: I/O options including Trip Coil Monitor, IRIG-B, and URTD Interface. Business Impact: Enhanced coordination with trip coils and time synchronization supports accurate protection sequencing. Application: Expands compatibility with existing protection architectures and legacy equipment. Feature: Removable terminals and semi-flush mounting simplify installation and maintenance. Business Impact: Faster commissioning, easier field servicing, and reduced downtime. Application: Panel builders appreciate straightforward wiring and service access.
Get a Quick Quote for a Eaton ETR-5000-2A3FA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2A3FA0?
Enquire Now
FAQs
Plan for semi-flush mounting and use the removable terminals to simplify wiring. The unit supports eight digital inputs and nine outputs, enabling integrated protection logic without excessive external relays. Ensure proper clearance for maintenance access and align the base relay with the ETR-4000 family for compatibility in mixed protection schemes.
The relay provides Modbus RTU or DNP3 RTU communications over fiber optic ST, enabling secure SCADA integration and remote diagnostics. Connect via fiber to your control center, configure the appropriate protocol in the device, and leverage supported metering and protection counters for event-driven alarms and logs.
Yes. The product is designed to work within Eaton’s transformer protection family and references a base relay ETR-4000. This enables seamless replacement or upgrade paths, leverages shared I/O concepts, and simplifies spare parts management and commissioning in established Eaton protection architectures.
Warranty is 25-000 with coverage of one year from installation or eighteen months from shipment, whichever occurs first. Compliance details are listed by the manufacturer and should be confirmed via Eaton’s official documentation to verify exact standards such as CE or SIL applicability for your installation.
Expect faster, coordinated protection actions with zone interlocking, reduced external wiring, and improved SCADA visibility through fiber-based communications. The device integrates protection, metering, and signaling in one package, lowering lifecycle costs and simplifying maintenance through removable terminals and straightforward installation.