Eaton ETR-5000-2A3IA1 Transformer Relay - 50/60 Hz

Part Number: ETR-5000-2A3IA1
Manufacturer
Eaton
Part number
ETR-5000-2A3IA1

Quick Summary

The Eaton transformer relay ETR-5000-2A3IA1 provides transformer protection for industrial power systems. Operators often struggle with false trips and slow fault diagnosis that extend downtime. Certification details vary by region; consult Eaton documentation for CE, SIL, and IP ratings applicable to your jurisdiction. This unit supports RS-485 and Ethernet communications, enabling rapid integration with modern protection schemes and SCADA. Designed with eight digital inputs and nine outputs, it supports zone selective interlocking and direct current sensing for precise control. Its wide power supply range and removable terminals simplify installation in mixed-voltage environments while reducing hardware diversity and lifecycle costs. The design supports future firmware updates and scalable protection features.

Product Information

Extended Description

ETR-5000-2A3IA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over RS-485, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection, Sensitive Ground InputTrip Coil Monitor,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A3IA1
UPC
786679155950
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input IRIG-B URTD Interface Trip Coil Monitor
Modbus / DNP3 RTU
over RS-485
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Voltage Protection and Metering Differential Protection Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
The transformer relay supports a wide power supply range of 19-300 Vdc and 40-250 Vac, with a 50/60 Hz frequency rating. This flexibility reduces the need for multiple regional variants and simplifies spare-part inventories, speeding up commissioning. In practice, technicians deploy the ETR-5000-2A3IA1 across mixed-voltage panels and transformer rooms, cutting wiring errors and project lead times. Eight digital inputs and nine outputs, with removable terminals and projection mounting, streamline wiring and maintenance. The compact, rugged projection-mount design saves panel space and supports quick field upgrades without rewiring. This translates into faster startup, easier expansion, and lower installation labor costs during retrofits. Modbus/RTU over RS-485 and Modbus/TCP over Ethernet RJ-45 provide versatile SCADA integration and remote diagnostics. Operators connect to existing control systems without custom adapters, leveraging standard protocols for alarms, metering, and setpoint updates. The result is faster fault isolation, better asset visibility, and reduced mean time to repair. I/O options such as Sensitive Ground Input, IRIG-B timing, URTD interface, and Trip Coil Monitor support advanced protection schemes and diagnostics, improving fault reporting and testability while ensuring reliability. Zone selective interlocking (ZSI) at 2 enables coordinated tripping that minimizes system disturbance and improves negotiability during sectional faults. Wide voltage and current sensing capabilities facilitate retrofit compatibility with legacy equipment and new protection architectures. Warranty coverage follows Eaton’s policy, with a one-year term from installation or eighteen months from shipment, whichever comes first.

Get a Quick Quote for a Eaton ETR-5000-2A3IA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A3IA1? Enquire Now

FAQs

Plan for its projection mounting and removable terminals to simplify wiring and field upgrades. Ensure a wide voltage supply is available (19-300 Vdc or 40-250 Vac) and allocate space for 8 digital inputs and 9 outputs. Use appropriate torque settings and labeled terminations to minimize wiring errors during commissioning and future expansions.
The relay supports Modbus RTU over RS-485 and Modbus TCP over Ethernet RJ-45. Connect to existing control networks using standard protocols for alarms, metering, and setpoint updates. For best results, use shielded cables for RS-485, ensure proper termination, and align baud rates with your SCADA master to optimize communication reliability.
Yes. With zone selective interlocking (2), 5 A and 1 A phase current sensing, and robust protection logic, it is designed for transformer protection across substations and manufacturing facilities. It supports mixed-voltage environments and integrates with protection schemes for fast fault isolation and reduced downtime.
Certification details vary by region. For global deployment, consult Eaton documentation for applicable CE, SIL, and IP ratings relevant to your jurisdiction. Ensure installation follows Eaton’s warranty policy and local electrical standards to maintain compliance and optimize lifecycle support.
Expect reduced downtime due to faster fault detection and isolation, consolidated protection electronics lowering spare-part inventory, and easier retrofits thanks to a wide input range and SCADA-ready communications. The removable terminals and projection mounting simplify maintenance, while Zone Selective Interlocking minimizes disturbance during fault events, improving overall plant availability.