Eaton ETR-5000-2A3LA0 Transformer Relay - 50/60 Hz

Part Number: ETR-5000-2A3LA0
Manufacturer
Eaton
Part number
ETR-5000-2A3LA0

Quick Summary

The Eaton transformer relay ETR-5000-2A3LA0 provides transformer protection for industrial power systems. Engineers seeking reliable protection across multiple feeders often face coordination gaps, miswiring, and limited visibility into protective actions. Compliance details are listed as 'Compliances: Contact Manufacturer'; this note highlights the need to request current certifications and installation guidance. This device supports remote monitoring via Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet and offers 50/60 Hz operation with 19-300 Vdc or 40-250 Vac power. By consolidating protection, metering, and communications in a single chassis, it reduces panel complexity and accelerates commissioning, while enabling interoperability with modern SCADA and OT networks. For engineers, this translates to faster fault isolation, easier maintenance planning, and improved uptime in substations and plant-level power distribution. Its robust IO and time synchronization options support precise protective schemes for critical loads.

Product Information

Extended Description

ETR-5000-2A3LA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A3LA0
UPC
786679156148
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
None
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor IRIG-B URTD Interface Sensitive Ground Input
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Differential Protection Power Protection and Metering Current Protection and Metering Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature: Flexible communications via Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet. Business Impact: Enables secure, real-time data exchange with SCADA, remote diagnostics, and centralized protection coordination. Application: Ideal for transformer protection and plant power monitoring in substations and distributed facilities. Long-tail keywords: Mbus TCP, DNP3 TCP/UDP, SCADA integration. Feature: Eight digital inputs and nine digital outputs plus two current-sensing inputs. Business Impact: Provides comprehensive protection and control without a separate I/O cabinet, reducing wiring complexity and installation time. Application: Protective relaying and metering for transformer circuits in industrial networks. Long-tail keywords: 8 DI, 9 DO, current sensing inputs, protection relay IO. Feature: Wide power supply and frequency range—19-300 Vdc / 40-250 Vac, 50/60 Hz. Business Impact: Flexible compatibility with mixed power architectures and aging plants, lowering conversion costs. Application: Retrofit or new builds across varied plants. Long-tail keywords: 19-300 Vdc, 40-250 Vac, 50/60 Hz compatibility. Feature: Built-in protection functions including Differential, Power, Current, and Voltage Protection and Metering. Business Impact: Delivers complete transformer protection within a single device, reducing downtime and improving protection coordination. Application: Substation transformer protection schemes and continuous metering. Long-tail keywords: differential protection, metering, transformer protection relay. Feature: I/O options such as Trip Coil Monitor, IRIG-B, URTD Interface, and Sensitive Ground Input; Zone Selective Interlocking. Business Impact: Enhances time synchronization, fault localization, and selective tripping with minimal outage impacts. Application: Critical electrical installations requiring fast, selective protection. Long-tail keywords: IRIG-B, URTD, Zone selective interlocking. Feature: Removable terminals and semi-flush mounting for easy installation and retrofit. Business Impact: Simplifies wiring, maintenance, and cabinet reconfiguration, accelerating deployment. Application: Retrofit projects and new installations in control panels and switchgear enclosures. Long-tail keywords: removable terminals, semi-flush mounting, easy installation.

Get a Quick Quote for a Eaton ETR-5000-2A3LA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A3LA0? Enquire Now

FAQs

When installing the ETR-5000-2A3LA0, plan for semi-flush mounting and removable terminals to simplify field wiring. Ensure the unit is housed in a compliant enclosure with adequate clearance for cooling and access to 19-300 Vdc or 40-250 Vac power, plus connections for 8 digital inputs and 9 digital outputs. Reference Eaton wiring diagrams and the ETR-5000-2A3LA0 specification sheet during commissioning.
The relay provides 8 digital inputs, 9 digital outputs, and 2 current-sensing inputs, powered from 19-300 Vdc or 40-250 Vac with 50/60 Hz operation. It supports Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet for SCADA integration, plus optional Zone Selective Interlocking and IRIG-B timing interfaces, enabling robust remote monitoring and coordinated protection.
Yes. The ETR-5000-2A3LA0 is designed for transformer protection and metering, offering differential, power, voltage, and current protection with integrated metering. Its flexible IO and secure communications with SCADA interfaces make it suitable for substations and plant-level transformer protection schemes, enabling fast fault isolation and accurate monitoring of transformer health.
Compliance details are listed as 'Compliances: Contact Manufacturer' on the datasheet. For formal certifications such as CE, SIL, or IP ratings, consult Eaton’s specification sheet (ETR-5000-2A3LA0) or contact Eaton directly to obtain the current, site-specific certification documentation and installation guidance.
Consolidating protection, metering, and communications into a single unit reduces panel count and wiring complexity, shortening commissioning time and lowering installation costs. Improved protection coordination minimizes downtime, while the device’s remote communication capabilities enable proactive maintenance. The warranty guidance aligns with Eaton policy (one year from installation or 18 months from shipment), supporting predictable lifecycle budgeting.