Eaton ETR-5000-2A3LB1 Transformer Relay - 50/60 Hz

Part Number: ETR-5000-2A3LB1
Manufacturer
Eaton
Part number
ETR-5000-2A3LB1

Quick Summary

Eaton transformer relay ETR-5000-2A3LB1 provides transformer protection for medium-voltage applications. Engineers often face integration challenges and risk misconfiguration when provisioning protection relays across Modbus, DNP3, or fiber Ethernet. Compliance specifics (CE, SIL, IP ratings) vary by installation; confirm exact certifications with Eaton, while the unit's 50/60 Hz operation and modular I/O support practical results. This design supports efficient power management and remote diagnostics, aligning with maintenance teams' needs for uptime and traceability.

Product Information

Extended Description

ETR-5000-2A3LB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2A3LB1
UPC
786679156377
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
0
Analog outputs
0
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor URTD Interface Sensitive Ground Input
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Differential Protection Current Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Feature: Eight digital inputs and nine digital outputs expand protection logic; Benefit: Enables complex protection schemes and precise fault signaling, reducing downtime; Application: Transformer protection networks in substations and OEM equipment. Feature: Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet for communications; Benefit: Enables seamless SCADA integration and remote diagnostics, cutting on-site visits; Application: Enterprise-wide monitoring of transformer assets. Feature: Power supply range 19-300 Vdc and 40-250 Vac with 50/60 Hz operation; Benefit: Global applicability reduces inventory and simplifies procurement; Application: Mixed-power environments across regions. Feature: Robust I/O options including IRIG-B, Trip Coil Monitor, and Sensitive Ground Input; Benefit: Flexible interfaces support legacy and modern protection architectures; Application: Retrofit projects and new installations. Feature: Removable terminals and projection mounting with conformal coating; Benefit: Easier installation, reliable field performance, and enhanced environmental tolerance; Application: Harsh industrial environments and field deployments.

Get a Quick Quote for a Eaton ETR-5000-2A3LB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2A3LB1? Enquire Now

FAQs

Plan for projection mounting with removable terminals to simplify field wiring. Verify compatible power supply within 19-300 Vdc or 40-250 Vac and ensure fiber Ethernet connectivity via Mbus TCP or DNP3 TCP/UDP. Prepare for environmental conditions by inspecting conformal-coated circuit boards and protective enclosures to maximize reliability in harsh industrial settings.
The unit supports Mbus TCP or DNP3 TCP/UDP communications over LC duplex fiber Ethernet, enabling seamless SCADA integration and remote diagnostics. Plan for network addressing, protocol mapping, and QoS to maintain deterministic communication, while leveraging its 8 DI / 9 DO I/O to implement clear protection logic signals.
Yes. The transformer relay is designed for a dual power range of 19-300 Vdc and 40-250 Vac with a 50/60 Hz frequency rating, enabling operation across diverse regions and applications without multiple SKUs. This flexibility reduces stocking complexity and simplifies field commissioning.
ETR-5000-2A3LB1 offers 8 digital inputs and 9 digital outputs, 2 current sensing inputs, and zone-selective interlocking with 2 zones. It supports IRIG-B, Trip Coil Monitor, URTD interface, and Sensitive Ground Input. These features enable comprehensive transformer protection, fast fault clearance, and compatibility with modern and legacy protection architectures.
The device’s removable terminals and conformal-coated boards simplify maintenance and field servicing, reducing downtime during inspections. Its fiber-based communications improve remote monitoring, lowering on-site visits. The robust protection capabilities help prevent transformer outages, delivering measurable uptime gains and a faster return on asset protection investments.