Eaton transformer relay ETR-5000-2B0BA0 - Modbus RTU

Part Number: ETR-5000-2B0BA0
Manufacturer
Eaton
Part number
ETR-5000-2B0BA0

Quick Summary

Eaton transformer relay is a protective monitoring device for transformer systems in industrial facilities. Design engineers often face nuisance trips and limited visibility into transformer health; this relay mitigates that with modular I/O and robust Modbus/DNP3 communications. Compliance details vary by market; consult the Eaton datasheets for CE, SIL, IP ratings where applicable. The solution enables transformer protection, metering, and remote diagnostics, helping you improve uptime, reduce maintenance costs, and ensure visibility across critical assets within substations and industrial plants.

Product Information

Extended Description

ETR-5000-2B0BA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B0BA0
UPC
786679156384
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor URTD Interface IRIG-B
Modbus / DNP3 RTU
over RS-485
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Differential Protection Current Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature → Business Impact → Application: The ETR-5000-2B0BA0 provides 2 analog inputs and 2 analog outputs paired with 8 digital inputs and 9 digital outputs, enabling precise protection and metering while supporting scalable monitoring for growing systems in OEM equipment and retrofits. This translates to improved protection coordination and data-rich diagnostics, reducing nuisance trips and enabling proactive maintenance in power distribution cabinets. Feature → Application: Modbus RTU or DNP3 RTU over RS485 enables seamless integration with SCADA and energy management systems, delivering remote monitoring and faster fault isolation for substations and manufacturing plants. Feature → Business Impact → Application: Power supply range from 19-300 Vdc and 40-250 Vac with 50/60 Hz operation, plus removable terminals and semi-flush mounting, streamlines installation, cabinet space planning, and field wiring. Feature → Application: I/O options including Trip Coil Monitor, URTD Interface, and IRIG-B enable advanced protection schemes and synchronization in complex control networks. Feature → Business Impact → Application: Compatibility with the ETR-4000 base relay ensures proven reliability and a familiar upgrade path for teams deploying Eaton’s transformer protection family, delivering lower training costs and faster commissioning. Feature → Application: The device’s protection and metering capabilities support regulatory compliance and performance reporting, supporting ROI through improved asset availability and data-driven maintenance planning.

Get a Quick Quote for a Eaton ETR-5000-2B0BA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2B0BA0? Enquire Now

FAQs

For installation, mount the unit using its semi-flush mounting method and connect the removable terminals. Power it from 19-300 Vdc or 40-250 Vac, then wire the 8 digital and 2 analog inputs, 9 outputs, and Modbus RS485 communications. Follow the included Eaton datasheets for wiring diagrams and sequence of operations to ensure proper protection and diagnostic access.
The relay supports voltage, current, differential, and power protection and metering with 2 analog inputs, 2 analog outputs, 8 digital inputs, and 9 digital outputs. Communications are via Modbus RTU or DNP3 RTU over RS485, enabling integration with SCADA systems and remote diagnostics.
Yes. With 50/60 Hz operation, a wide power supply range, and the ability to monitor multiple protection parameters, the ETR-5000-2B0BA0 is well-suited for transformer protection in substations and industrial plants, offering reliable trip coordination and data for asset health monitoring.
Compliance details are market-dependent. Refer to Eaton's datasheets and the provided downloads for certification information (CE, SIL, IP ratings where applicable). When in doubt, contact Eaton support to confirm current certifications for your region and application.
ROI is driven by reduced downtime, fewer nuisance trips, and improved maintenance planning through remote monitoring and diagnostics. The device’s warranty (one year from installation or 18 months from shipment) reflects confidence in reliability, while its integration with Eaton’s protection ecosystem lowers training and commissioning costs.