Eaton ETR-5000-2B0DA1 Transformer Relay - Profibus-DP
Part Number: ETR-5000-2B0DA1
Quick Summary
Eaton transformer relay provides transformer protection and monitoring for industrial power systems. Many teams wrestle with wiring complexity and slow fault diagnostics across feeders; this unit consolidates protection, metering, and communications in a single module. Certification specifics vary by region; verify CE, SIL, and IP ratings with the manufacturer before purchase. With Profibus-DP communication over fiber, removable terminals, and scalable I/O, it enables faster deployments and reliable protection in transformer applications.
Product Information
Extended Description
ETR-5000-2B0DA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Profibus-DP , 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9, Removable, Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz,Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B0DA1
UPC
786679156797
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
None
Communication
Profibus-DP over Fiber Optic ST
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B URTD Interface Trip Coil Monitor
Phase current
5A, 1A
PROFIBUS-DP
over fiber optic ST
Sensing inputs
Power Protection and Metering Current Protection and Metering Voltage Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Eaton Specification Sheet - ETR-5000-2B0DA1
Feature: Eight digital inputs and nine outputs provide extensive field I/O without external relays. Business Impact: Reduces panel size and wiring hours, lowering installation costs while improving fault visibility. Application: Transformer protection and monitoring in new builds or retrofit projects benefit from compact integration. Feature: Two analog inputs and two analog outputs with 50/60 Hz compatibility. Business Impact: Enables accurate metering and control signaling for protection schemes, improving diagnostic precision and reducing nuisance trips. Application: Power protection and metering across feeders and transformer banks. Feature: PROFIBUS-DP over fiber optic ST communication. Business Impact: Delivers EMI-immune, robust communication to control systems and OEM equipment, shortening commissioning times. Application: OEM machine builds and substation panels requiring reliable data exchange. Feature: I/O options including IRIG-B URTD interface and Trip Coil Monitor. Business Impact: Supports exact time synchronization and rapid trip confirmation, enhancing safety and coordination. Application: Critical protection in high-availability plants with precise event logging. Feature: Zone selective interlocking and removable terminals. Business Impact: Improves selectivity and reduces outage impact while simplifying maintenance and field swaps. Application: Medium to large transformer installations needing fast, coordinated tripping. Feature: ETR-4000 base compatibility and modular design. Business Impact: Enables easier upgrades and spare-part substitutions, protecting long-term investment. Application: Retrofit programs where existing ETR-4000 baselines are expanded with new capabilities.
Get a Quick Quote for a Eaton ETR-5000-2B0DA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2B0DA1?
Enquire Now
FAQs
Begin with the 8 digital inputs and 9 outputs layout to minimize external I/O modules. Use removable terminals for quick terminations and connect the 19-300 VDC or 40-250 VAC power supply as specified. Plan for Profibus-DP communication via fiber optic ST to ensure EMI resistance and reliable data exchange with the PLC or protection system.
Key specs include 50/60 Hz operation, dual analog inputs and outputs for metering, 8 digital inputs and 9 digital outputs for logic and signaling, and a broad power range (19-300 VDC, 40-250 VAC). The unit also supports current, voltage, differential protection sensing and zone selective interlocking for selective tripping.
Yes. The relay supports Profibus-DP over fiber optic ST, providing reliable, EMI-immune communication to control systems and OEM equipment, which reduces wiring complexity and simplifies commissioning in factory and substation environments.
Certification specifics vary by region and application. The datasheet notes 'Compliances: Contact Manufacturer'; therefore, confirm CE, SIL, IP, or other regional requirements with Eaton before procurement and installation to ensure regulatory alignment.
The device ships with a one-year warranty or 18 months from shipment, whichever occurs first, aiding risk management. Its integrated I/O, IK-protected communication, and remover terminals reduce wiring, maintenance time, and spares inventory, delivering lower total cost of ownership in transformer protection deployments.