Eaton ETR-5000-2B0HA0 Transformer Relay - 61850

Part Number: ETR-5000-2B0HA0
Manufacturer
Eaton
Part number
ETR-5000-2B0HA0

Quick Summary

Eaton transformer relay ETR-5000-2B0HA0 provides comprehensive transformer protection and metering for industrial power systems. Engineers often struggle with fault isolation, slow diagnostics, and coordinating protection across multiple networks. Note that explicit CE, UL, or IP certifications are not listed in the data—verify with the manufacturer. By leveraging Ethernet-based communications (IEC 61850, M-Bus TCP, DNP3 TCP/UDP), 8 digital inputs, 9 digital outputs, and dual power options (19-300 VDC or 40-250 VAC), it enables fast, scalable protection while reducing integration effort and lifecycle costs.

Product Information

Extended Description

ETR-5000-2B0HA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz ,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B0HA0
UPC
786679157671
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
None
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor URTD Interface IRIG-B
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Differential Protection Current Protection and Metering Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature: Flexible power supply range and I/O; Business Impact: Enables installation in varied environments and simplifies panel design, reducing wiring time and error potential; Application: Suitable for MCCs and transformer enclosures where supply rails vary. Feature: Ethernet communications with IEC 61850, M-Bus TCP, and DNP3 TCP/UDP; Business Impact: Seamless integration with modern SCADA and substation automation systems, enabling real-time monitoring and faster fault diagnosis; Application: Substation transformer protection and remote metering. Feature: Eight digital inputs and nine outputs plus two analog inputs and two analog outputs; Business Impact: Rich I/O supports complex protection schemes and programmable logic, lowering the need for external modules; Application: Local control and protection logic within compact panels. Feature: Removable terminals and semi-flush mounting; Business Impact: Easier installation and maintenance with reduced field wiring complexity; Application: Front-access wiring in restricted-door panels. Feature: Power supply range 19-300VDC and 40-250VAC plus 50/60 Hz operation; Business Impact: Versatile installation across diverse facilities, improving uptime and reducing spare parts. Feature: I/O options like Trip Coil Monitor and IRIG-B; Business Impact: Enhanced protection coordination and time synchronization for precise event logging; Application: Industrial power protection and transformer protection relays.

Get a Quick Quote for a Eaton ETR-5000-2B0HA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2B0HA0? Enquire Now

FAQs

Installation uses removable terminals and semi-flush mounting for straightforward panel fitment. The unit supports 8 digital inputs, 9 digital outputs, 2 analog inputs and 2 analog outputs. Power the relay from 19-300V DC or 40-250V AC, and plan for 50/60 Hz operation. Follow Eaton guidelines and use PowerPort-E for advanced configuration to simplify setup.
The ETR-5000 provides Ethernet-based communications with IEC 61850, M-Bus TCP, and DNP3 TCP/UDP. It also supports Modbus via TCP and local analytics through the analog/digital I/O. This broad protocol support enables seamless integration with modern SCADA, historian, and protection schemes, reducing integration time and risk.
Yes. With 8 digital inputs, 9 outputs, 2 analog inputs, 2 analog outputs, and a dual power supply range, the relay supports transformer protection and metering in substations and MCCs. Its Ethernet-based coordination, Zone Selective Interlocking capability, and time-stamped event logging enhance fault isolation and operator situational awareness.
Documentation lists Compliances as 'Contact Manufacturer', so verify CE, UL, IP ratings, and other certifications directly with Eaton. Review the Eaton specification sheet and datasheet for the ETR-5000-2B0HA0 to ensure compliance with local electrical standards before procurement and installation.
Expect reduced downtime through faster fault isolation and improved protection coordination. The device consolidates protection, metering, and communication in a single relay, lowering panel complexity and spare parts. A one-year warranty (or 18 months from shipment) adds risk mitigation, while remote diagnostics and PowerPort-E configuration shorten commissioning time.