Eaton ETR-5000-2B0HB0 Transformer Relay - 61850/DNP3 TCP

Part Number: ETR-5000-2B0HB0
Manufacturer
Eaton
Part number
ETR-5000-2B0HB0

Quick Summary

An Eaton transformer relay, the ETR-5000-2B0HB0, protects transformers in utility, industrial, and OEM power systems. It addresses outages caused by undetected faults and adds real-time protection to avoid costly equipment damage. For certifications, compliance details are provided by the manufacturer; typical approvals include CE markings and regional certifications—consult Eaton for exact SIL, CE, and IP ratings. This solution also integrates with IEC 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet, enabling scalable protection workflows. By combining broad compatibility with a wide input range, it delivers reliable protection and diagnostic insight for modern power networks, while reducing spare parts and support costs.

Product Information

Extended Description

ETR-5000-2B0HB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz ,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B0HB0
UPC
786679157657
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface IRIG-B Trip Coil Monitor
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Voltage Protection and Metering Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature → Business Impact → Application: The ETR-5000-2B0HB0 offers eight digital inputs, nine digital outputs, two analog inputs, and two analog outputs, enabling sophisticated transformer protection schemes and fast fault signaling. This IO density translates into precise control logic, improved fault isolation, and reduced downtime for substations, OEM power equipment, and plant transformers. Application-wise, it supports protection, metering, and monitoring across utility and industrial networks, enabling operators to implement zone selective interlocking and coordinated protection strategies. Feature → Business Impact → Application: The device supports a broad power supply range of 19-300Vdc and 40-250Vac, along with a 50/60 Hz frequency rating, ensuring operation from diverse sources and in varied environments. This versatility reduces the need for multiple power supplies and simplifies spares management in multi-site deployments. Application-wise, it is well-suited for retrofits and new installations in substations and industrial facilities seeking reliable transformer protection without complex power configurations. Feature → Business Impact → Application: Communication options including IEC 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet RJ45 enable seamless integration with modern protection architectures and SCADA systems. This accelerates data sharing, diagnostics, and remote maintenance, lowering engineering effort and commissioning time. Application-wise, it supports OEMs and utilities deploying unified Ethernet-based protection schemes across fleets. Feature → Business Impact → Application: Conformal coating, removable terminals, and semi-flush mounting improve field reliability and ease of maintenance. These features reduce diagnostic downtime, simplify terminal access during upgrades, and support rugged installation in harsh environments. Application-wise, it benefits retrofit projects and new builds in harsh industrial settings where reliability and serviceability are critical. Feature → Business Impact → Application: I/O options such as URTD Interface, IRIG-B time synchronization, and Trip Coil Monitor provide advanced timing, monitoring, and trip-coil integrity, enhancing protection accuracy and maintenance planning. Application-wise, this is advantageous for high-availability electrical networks, where precise timing and robust trip signaling are essential for safe transformer operation.

Get a Quick Quote for a Eaton ETR-5000-2B0HB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2B0HB0? Enquire Now

FAQs

Yes. The ETR-5000-2B0HB0 is designed as an enhanced transformer protection relay that builds on the ETR-4000 base, providing additional analog and digital I/O, expanded communications, and improved protection features while remaining compatible with the base architecture for straightforward retrofits and upgrades.
The relay supports IEC 61850 for modern substation automation, M-Bus TCP for metering integrations, and DNP3 TCP/UDP over Ethernet RJ45 for SCADA interoperability. These protocols enable seamless data exchange, remote diagnostics, and coordinated protection across multi-vendor networks.
The device operates from a wide range power supply: 19-300 VDC or 40-250 VAC, with a 50/60 Hz frequency rating. This flexibility supports diverse installations, simplifies site wiring, and reduces the need for multiple power converters in mixed power environments.
This transformer relay is intended for transformer protection in utility substations, industrial plants, and OEM equipment. It combines protection, metering, and diagnostics with robust Ethernet communications to support reliable transformer operation and rapid fault isolation.
Removable terminals and semi-flush mounting simplify field wiring and service access, while conformal coating enhances reliability in harsh environments. Extended I/O options, including URTD, IRIG-B timing, and Trip Coil Monitor, improve protection accuracy and enable easier maintenance planning in complex protection schemes.