Eaton ETR-5000-2B0HB1 Transformer relay - 61850/Mbus TCP

Part Number: ETR-5000-2B0HB1
Manufacturer
Eaton
Part number
ETR-5000-2B0HB1

Quick Summary

Eaton transformer relay protects transformer assets in industrial power systems with intelligent monitoring. Engineers often wrestle with coordinating protection, metering, and remote diagnostics across multiple sites, and legacy relays can complicate integration. Typical certifications to confirm include CE marking, RoHS compliance, and UL/CSA recognition—verify for this model with Eaton. Designed for transformer protection, metering, and data exchange over Ethernet, it enables faster troubleshooting and scalable control-panel deployment. By supporting IEC 61850, M-Bus TCP, and DNP3 TCP/UDP, the unit aligns with modern digital substations and OEM uses.

Product Information

Extended Description

ETR-5000-2B0HB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz, Projection
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B0HB1
UPC
786679157466
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B URTD Interface Trip Coil Monitor
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Differential Protection Voltage Protection and Metering Power Protection and Metering Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Feature → Business Impact → Application: 8 digital inputs and 9 outputs allow comprehensive protection logic and status signaling directly at the device, reducing wiring complexity and enabling faster fault isolation in switchgear and distribution panels. This translates to measurable reductions in switchgear downtime and improved MTBF for transformer assemblies, especially in high-density control rooms and outdoor substations. Feature → Application: Analog inputs (2) and current sensing inputs (2) enable differential and metering capability within a single package, supporting accurate energy accounting and transformer health monitoring across 50/60 Hz systems. This supports cost reduction through fewer separate metering devices and simplified commissioning during panel buildouts. Feature → Business Impact → Application: Power supply options 19-300Vdc and 40-250Vac ensure compatibility with varied plant supplies, easing installation in retrofit projects and new builds alike, while minimizing the need for voltage converters or power interfaces. Application: transformer protection relays in OEM equipment and retrofit projects. Feature → Application: Ethernet RJ-45 with 61850, Mbus TCP, or DNP3 TCP/UDP enables remote diagnostics and integration with substation automation systems, improving asset visibility and accelerating issue resolution for distributed assets. Feature → Business Impact → Application: Removable terminals and projection mounting simplify installation and maintenance in tight spaces, reduce field wiring errors, and improve serviceability in cabinets, control rooms, and outdoor enclosures. Feature → Application: IRIG-B URTD Interface and Trip Coil Monitor provide advanced synchronization and trip monitoring for critical transformer protection schemes, supporting zone selective interlocking and coordinated protection in medium- and high-voltage environments. Feature → Business Impact → Application: Base relay compatibility with ETR-4000 ensures a known, upgradeable platform path, minimizing engineering rework and enabling seamless migration for existing Eaton protection schemes.

Get a Quick Quote for a Eaton ETR-5000-2B0HB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2B0HB1? Enquire Now

FAQs

The ETR-5000-2B0HB1 uses removable terminals and projection mounting for straightforward panel installation. Verify compatibility with 19-300Vdc or 40-250Vac power, connect the 61850/Mbus/DNP3 network over Ethernet RJ-45, and wire the 8 inputs and 9 outputs according to your protection scheme to minimize rework and commissioning time.
Expect 8 digital inputs, 9 outputs, 2 analog inputs, and 2 current sensing inputs supporting differential, voltage, and metering protection. Operating at 50/60 Hz with a wide power-supply range (19-300Vdc, 40-250Vac) enables accurate protection logic and metering across diverse plant electrical systems.
Yes, the unit supports IEC 61850 over Ethernet RJ45, along with M-Bus TCP and DNP3 TCP/UDP, enabling seamless integration with substation automation and OEM monitoring systems for remote diagnostics, event reporting, and coordinated protection.
Confirm CE marking, RoHS compliance, and UL/CSA recognitions with Eaton for this model, and ensure any local regulatory requirements for transformer protection relays are met in your facility. Verify network protocol support (61850, M-Bus TCP, DNP3) aligns with your SCADA architecture.
Consolidating protection, metering, and communications reduces hardware counts, wiring, and commissioning time, delivering lower CAPEX and OPEX. Remote diagnostics and fast fault isolation improve MTTR, while the base ETR-4000 compatibility supports smooth system upgrades and lifecycle management.