Eaton ETR-5000-2B0KA0 Protection Relay - Differential

Part Number: ETR-5000-2B0KA0
Manufacturer
Eaton
Part number
ETR-5000-2B0KA0

Quick Summary

An Eaton transformer relay is designed to protect transformers in industrial power systems, delivering fast protection and precise metering. Many panel installations face complex protection schemes, wiring challenges, and delayed fault isolation that increase downtime and maintenance costs. Compliances are listed as Contact Manufacturer; in practice, applications often require standard considerations such as SIL, CE, or IP-rated enclosures, which should be verified with Eaton for your environment. With wide input support, time-synced monitoring, and robust communications, the ETR-5000-2B0KA0 simplifies integration and ongoing diagnostics. For engineers and buyers, this relay delivers reliability, visibility into transformer health, and scalable connectivity via Modbus/DNP3 TCP over fiber.

Product Information

Extended Description

ETR-5000-2B0KA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9, Removable, Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz Differential Protection, Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B0KA0
UPC
786679157831
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
None
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor IRIG-B URTD Interface
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection Voltage Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature: Comprehensive transformer protection including Differential Protection, Voltage Protection and Metering, and Power Protection and Metering. Benefit: Reduces fault severity and speeds fault isolation, minimizing equipment damage and downtime; Application: Substation and transformer protection schemes where precise protection is critical. Feature: Extensive I/O and modular design with 8 digital inputs, 9 outputs, and 2 analog inputs/outputs. Benefit: Flexible wiring and fast integration into existing control architectures; Application: Retrofit or new installations requiring rich signaling and metering. Feature: Wide power supply range 19-300 Vdc / 40-250 Vac and 50/60 Hz operation. Benefit: Supports varied field voltages, easing onsite wiring and improving reliability; Application: Power distribution and OEM equipment in harsh environments. Feature: Communications and timing options including Modbus/DNP3 TCP over LC duplex fiber, IRIG-B, and URTD Interface. Benefit: Enables robust, time-synced data exchange and remote monitoring; Application: Networked protection schemes with centralized visibility. Feature: Removable terminals and semi-flush mounting with a base relay (ETR-4000). Benefit: Simplifies field wiring, testing, and future upgrades; Application: Panel assemblies and retrofit projects where serviceability matters.

Get a Quick Quote for a Eaton ETR-5000-2B0KA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2B0KA0? Enquire Now

FAQs

Install the unit using the semi-flush mounting method and secure the removable terminals for wire access. Start with powering the device from 19–300 Vdc or 40–250 Vac, then connect the 8 digital inputs, 2 analog inputs, and 2 analog outputs along with the 9 outputs as required. Configure communications (Modbus/DNP3 TCP over fiber) and, if needed, enable IRIG-B timing for synchronized operations. This approach minimizes wiring errors and speeds commissioning while preserving future expandability via the ETR-4000 base.
Key specs include a power supply range of 19–300 Vdc and 40–250 Vac, operation at 50/60 Hz, 8 digital inputs, 9 digital outputs, 2 analog inputs, and 2 analog outputs. Protection features cover Current Protection and Metering, Differential Protection, Voltage Protection and Metering, and Power Protection and Metering. Communication options include Modbus and DNP3 TCP over LC duplex fiber, with IRIG-B timing and a Trip Coil Monitor for enhanced reliability.
Yes. The relay is designed for transformer protection, offering differential protection and metering alongside voltage and power protection. Its wide input range, rich I/O (8/9 channels), and robust fiber-based communications support integration into substations and OEM equipment. Features like URTD interface and IRIG-B timing improve synchronization and interoperability, making it suitable for both new installations and retrofit projects.
Compliances are listed as Contact Manufacturer, so confirm applicable certifications with Eaton for your installation. While typical practices emphasize CE, SIL, and IP considerations, exact certifications can vary by model and region. When engineering critical protection schemes, verify the precise regulatory approvals and testing requirements with Eaton to ensure the device meets your safety and reliability standards.
The ETR-5000-2B0KA0 supports remote monitoring via Modbus/DNP3 TCP, which enables proactive diagnostics and reduced on-site visits. Its removable terminals simplify wiring and maintenance, and Trip Coil Monitor reduces unrepaired faults by providing continuous protection visibility. Combined with a typical one-year warranty (or 18 months from shipment), these features contribute to lower downtime and faster fault resolution, delivering a favorable total cost of ownership.