The Eaton transformer relay ETR-5000-2B1FB1 provides advanced protection for transformer networks in industrial facilities. Engineers often struggle to coordinate protection logic across multiple inputs while maintaining reliability under fault conditions. Certification expectations vary by region, so consult Eaton’s official datasheets for CE marking, SIL readiness, and IP ratings. This device offers Modbus RTU or DNP3 RTU over fiber, eight digital inputs and nine outputs, and dual analog I/O, delivering a compact, scalable solution for modern control architectures in industrial automation. With its conformal-coated boards and time-synchronization options, it supports robust deployments, reduces field wiring, and simplifies integration with existing protective-relay schemes and SCADA systems.
Product Information
Extended Description
ETR-5000-2B1FB1 Eaton: Eaton transformer relay, Modbus RTU or DNP3 RTU , 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input, IRIG-B, URTD Interface, Trip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B1FB1
UPC
786679155998
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over Fiber Optic ST
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input IRIG-B URTD Interface Trip Coil Monitor
Modbus / DNP3 RTU
over fiber optic ST
Phase current
5A, 1A
Sensing inputs
Differential Protection Current Protection and Metering Voltage Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
E-series protective relays
E-series protective relays
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Eaton Specification Sheet - ETR-5000-2B1FB1
Feature: Modbus RTU or DNP3 RTU over fiber optic ST connectivity enables EMI-immune, long-distance communication. Business Impact: Improves reliability and security of remote monitoring and control. Application: Suitable for transformer protection across distributed facilities and substations, reducing false trips and enabling centralized supervision. Feature: Eight digital inputs and nine outputs plus two analog inputs and two analog outputs provide flexible protection logic. Business Impact: Simplifies wiring, reduces panel space, and enables more comprehensive protection schemes. Application: Ideal for integrated control with PLCs and SCADA in manufacturing plants and utility environments. Feature: Wide power-supply range of 19-300 Vdc and 40-250 Vac with 50/60 Hz support. Business Impact: Enables global deployments with a single device without multiple power converters. Application: Global substations and industrial sites with varied power ecosystems. Feature: I/O options including Sensitive Ground Input, IRIG-B, URTD Interface, and Trip Coil Monitor. Business Impact: Improves fault diagnosis, time synchronization, and coordinated interlocking for safer, faster trips. Application: Critical feeder protection and turbine/generator applications. Feature: Conformal coating, projection mounting, and removable terminals. Business Impact: Enhances reliability in harsh environments and eases field installation and maintenance. Application: Harsh industrial environments and modular panels. Feature: Comprehensive sensing including Differential Protection, Current Protection & Metering, Voltage Protection & Metering, and Power Protection & Metering. Business Impact: Delivers holistic protection with metering for energy management and fault analysis. Application: Transformer protection suites in data centers and heavy industry.
Get a Quick Quote for a Eaton ETR-5000-2B1FB1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2B1FB1?
Enquire Now
FAQs
The ETR-5000-2B1FB1 is designed for projection mounting with removable terminals to ease field wiring. It provides eight digital inputs, nine outputs, and two analog inputs/outputs, enabling flexible protection logic. Plan for fiber optic connections for Modbus RTU or DNP3 RTU, and confirm conduit and enclosure ratings match your site conditions. Ensure proper time synchronization interfaces, such as IRIG-B or URTD, are accessible for coordinated protection schemes.
Fiber optic communication eliminates EMI and crosstalk common in harsh electrical environments, enabling robust remote monitoring and control. Modbus RTU or DNP3 RTU over fiber ensures secure, deterministic data exchange with PLCs/SCADA. This reduces miscommunication during faults and supports faster, coordinated protection actions across distributed transformer protection networks.
Yes. The device supports a wide power range of 19-300 Vdc and 40-250 Vac with 50/60 Hz operation, accommodating diverse regional power systems. This flexibility simplifies international deployments and reduces the need for multiple relays across sites, supporting consistent protection logic and metering across the enterprise.
It provides differential protection, current protection and metering, voltage protection and metering, and power protection and metering, backed by two current-sensing inputs. With eight digital inputs and nine outputs plus 2 analog inputs/outputs, you can implement zone-selective interlocking and detailed fault diagnostics to improve reliability and fault-clearing speed.
The product is supported by Eaton documentation, including specification sheets and datasheets. Warranty terms follow Eaton policy: one year from installation or 18 months from shipment, whichever occurs first. For precise compliance details, review the Eaton datasheets and the E-series protective relay literature provided in the downloads.