Eaton transformer relay ETR-5000-2B1KA1 - 50/60 Hz

Part Number: ETR-5000-2B1KA1
Manufacturer
Eaton
Part number
ETR-5000-2B1KA1

Quick Summary

Eaton transformer relay protects transformers by monitoring voltage, current, and faults to trigger fast protective action in industrial power systems. Engineers often struggle with nuisance trips and slow fault isolation; this relay offers configurable protections, accurate sensing, and robust diagnostics to minimize downtime and improve reliability. Compliance details are not listed in this data; confirm certifications with the manufacturer. In practice, these protections enable seamless integration with plant automation and remote monitoring via Modbus / DNP3 TCP over fiber, delivering tangible business value through safer operation and easier maintenance.

Product Information

Extended Description

ETR-5000-2B1KA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection, Sensitive Ground InputTrip Coil Monitor,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B1KA1
UPC
786679156612
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
None
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input IRIG-B Trip Coil Monitor URTD Interface
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Current Protection and Metering Differential Protection Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Feature → Business Impact → Application: 8 digital inputs and 9 digital outputs provide expansive logic control and wiring flexibility, reducing panel space and wiring errors while enabling sophisticated protection schemes for transformers in utility substations or industrial plants. This translates to faster commissioning, lower lifecycle costs, and improved fault isolation in harsh environments. Feature → Business Impact → Application: 2 analog inputs and 2 analog outputs support metering and differential protection signals, enabling precise monitoring of voltage, current, and transformer health data for proactive maintenance programs. Application: transformer protection and motor-control centers requiring accurate sensing and remote diagnostics. Feature → Business Impact → Application: Wide power-supply range (19–300 Vdc, 40–250 Vac) and 50/60 Hz compatibility ensure compatibility with diverse plant voltages, simplifying installation and reducing the need for additional power converters. Application: multinational facilities with mixed voltage ecosystems. Feature → Business Impact → Application: Projection mounting and removable terminals enhance field installation speed and reliability, especially in retrofit projects or cabinets with space constraints. Application: retrofit installations and new builds with tight timelines. Feature → Business Impact → Application: I/O options including Sensitive Ground Input, IRIG-B, Trip Coil Monitor, and URTD interface deliver precise protection coordination and advanced diagnostics for critical transformer protection scenarios. Application: substations and heavy-industry plants demanding accurate trip signals and interlocking. Feature → Business Impact → Application: Modbus / DNP3 TCP over LC duplex fiber enables robust SCADA and historian integration, improving remote monitoring, event logging, and predictive maintenance. Application: plant-wide automation architectures and utility-scale networks. Feature → Business Impact → Application: Backward compatibility with the ETR-4000 base relay simplifies upgrade paths, protecting existing investment while expanding functionality. Application: upgrade programs and OEM deployments across established Eaton protection relays.

Get a Quick Quote for a Eaton ETR-5000-2B1KA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2B1KA1? Enquire Now

FAQs

Begin by confirming the ETR-4000 as the base relay and ensure the new unit is physically compatible for projection mounting. Remove and re-seat removable terminals as needed, then connect the eight digital inputs and nine outputs according to the control schematic. Verify power connections within the 19–300 Vdc / 40–250 Vac range and test the protective logic offline before energizing the system. This approach minimizes commissioning time and reduces the risk of mis-wiring during a retrofit.
Confirm power supply range (19–300 Vdc or 40–250 Vac) and frequency rating (50/60 Hz). Validate eight digital inputs and nine digital outputs, plus two analog inputs and two analog outputs for metering and protection signals. Ensure the phase current options (5 A and 1 A) align with your CT configurations and that the module supports the IRIG-B, Trip Coil Monitor, and Sensitive Ground Input options required by your protection scheme.
Yes. The ETR-5000-2B1KA1 supports Modbus / DNP3 TCP communications over LC duplex fiber, enabling reliable integration with SCADA and historian systems. This facilitates remote monitoring, event analysis, and coordinated protection across distributed assets, which is essential for large factories and substations that require centralized visibility.
Compliance details are not listed in the provided data; please contact the manufacturer to confirm certifications applicable to your region and use case. In practice, transformer protection relays commonly align with industry standards, so verify CE, SIL, IP ratings, or other relevant approvals with Eaton prior to procurement.
By consolidating protection, metering, and communication into a single transformer relay, you reduce hardware footprint, simplify wiring, and accelerate commissioning. The expanded I/O, remote communication, and diagnostic capabilities support predictive maintenance, lowering unplanned outages and extending transformer life. Retrofit projects benefit from backward compatibility with the ETR-4000 base while enabling modern monitoring and integration with existing SCADA systems.