Eaton ETR-5000-2B2BA0 Transformer Relay - RS-485 Modbus
Part Number: ETR-5000-2B2BA0
Quick Summary
The Eaton ETR-5000-2B2BA0 Transformer Relay protects transformers in industrial power systems. This device addresses downtime and fault-finding challenges by providing robust protection and modular I/O. Note: exact certifications are not listed; verify CE, SIL, or IP ratings with Eaton for your compliance needs. With Modbus RTU or DNP3 RTU over RS-485, and 8 digital inputs, 9 outputs, plus 2 analog inputs and 2 analog outputs, it integrates into new or retrofitted installations. The device also supports a wide power range (19-300 VDC, 40-250 VAC) and 50/60 Hz operation, delivering reliable transformer protection in demanding environments. Its built-in gateway capabilities and anti-floating design simplify diagnostics and reduce maintenance costs.
Product Information
Extended Description
ETR-5000-2B2BA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz ,Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B2BA0
UPC
786679157015
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface IRIG-B Trip Coil Monitor Sensitive Ground Input
Modbus / DNP3 RTU
over RS-485
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Differential Protection Current Protection and Metering Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
E-series protective relays
E-series protective relays
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Eaton Specification Sheet - ETR-5000-2B2BA0
Feature → Business Impact → Application: 8 digital inputs and 9 digital outputs enable comprehensive control and fault signaling, improving visibility and fault isolation in transformer protection panels; this reduces unplanned downtime and accelerates automated interlocks in distribution centers. Feature → Business Impact → Application: 2 analog inputs and 2 analog outputs support metering and protection signaling, enabling accurate load monitoring and differential protection signals for feeders in substations. Feature → Business Impact → Application: Modbus RTU or DNP3 RTU over RS-485 provides industry-standard communication, allowing seamless integration with SCADA, EMS, and PLCs for centralized monitoring and remote diagnostics. Feature → Business Impact → Application: Universal power-supply range of 19-300 VDC and 40-250 VAC supports both new installations and retrofits, simplifying replacement without power-system downtime. Feature → Business Impact → Application: 50/60 Hz operation and phase current options (5 A, 1 A) ensure compatibility with global transformer protection schemes, reducing engineering effort and scaling smoothly as plant demands grow. Feature → Business Impact → Application: Removable terminals and semi-flush mounting enable quick wiring changes and easier service, while URTD interface, IRIG-B, and Sensitive Ground Input options improve diagnostics and protection accuracy in complex environments. Warranty and support considerations, including a one-year minimum warranty (or 18 months from shipment), help manage lifecycle and maintenance budgets while ensuring access to Eaton’s technical resources.
Get a Quick Quote for a Eaton ETR-5000-2B2BA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2B2BA0?
Enquire Now
FAQs
Begin by confirming panel clearance and mounting the relay with semi-flush support. Use the removable terminals to connect 8 digital inputs, 9 digital outputs, 2 analog inputs, and 2 analog outputs. Connect the RS-485 communication lines for Modbus RTU or DNP3 RTU, wire the protective grounds as applicable, and supply power within the 19-300 VDC / 40-250 VAC range. After wiring, use the front panel or software to configure protection parameters and I/O logic.
The ETR-5000-2B2BA0 supports Modbus RTU or DNP3 RTU over RS-485. Start by wiring the RS-485 pair to the controller network, assign a unique Modbus or DNP3 address, and set baud rate, parity, and stop bits per your system. Use Eaton’s configuration tools or the front panel to map inputs/outputs to protection functions, alarms, and metering signals, enabling scalable integration with SCADA and PLCs.
Yes. The relay is designed for 50/60 Hz operation and accepts a broad power range of 19-300 VDC or 40-250 VAC. This makes it compatible with global transformer protection schemes and allows seamless retrofits in existing 3-phase and single-phase transformer panels without major power-system changes.
The relay supports differential protection and voltage/current protection with metering capabilities, along with zone selective interlocking (2). It provides robust transformer protection, remote diagnostics via RS-485 networks, and flexible I/O for signaling and interlocks. It’s well-suited for substations, switchgear, and plant distribution panels requiring fast fault isolation and reliable monitoring.
Eaton offers a warranty policy of one year from installation or eighteen months from shipment, whichever occurs first. For technical support, calibration, and service options, contact Eaton's support channels or a certified Eaton distributor. This ensures access to firmware updates, documentation, and field service if needed.