Eaton ETR-5000-2B2BB1 Transformer Relay - Modbus RTU over RS485
Part Number: ETR-5000-2B2BB1
Quick Summary
Eaton transformer relay ETR-5000-2B2BB1 protects transformers and monitors feeders in industrial power systems. Users often struggle with integrating protection logic into existing control architectures and ensuring reliable communication with SCADA. Certifications like CE marking, SIL capability, and IP-rated enclosures are typically pursued for safety and reliability; confirm exact listings with Eaton. This device combines 8 digital inputs, 9 digital outputs, 2 analog I/O, and supports Modbus RTU or DNP3 RTU over RS485, delivering scalable protection that integrates smoothly with modern automation networks and digital plant environments.
Product Information
Extended Description
ETR-5000-2B2BB1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over RS-485,19-300Vdc, 40-250Vac, 50/60 Hz, ProjectionSensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B2BB1
UPC
786679157046
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Trip Coil Monitor Sensitive Ground Input IRIG-B
Modbus / DNP3 RTU
over RS-485
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Differential Protection Current Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
E-series protective relays
E-series protective relays
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Interfacing with an Eaton E-Series Relay, Step 6: Front Panel Navigation
Eaton Specification Sheet - ETR-5000-2B2BB1
Feature: Modbus RTU or DNP3 RTU over RS485 enables seamless SCADA integration. Benefit: Improved remote monitoring and control reduces现场现场 downtime and speeds fault isolation in transformer protection schemes. Application: Suitable for substations and industrial plants needing reliable communications and centralized alarm management. Feature: 8 digital inputs, 9 outputs, and 2 analog I/O provide flexible protection logic and metering options. Benefit: Supports complex protection schemes without adding external I/O hardware, lowering panel footprint and wiring costs. Application: Ideal for transformer protection, metering, and coordination with other protective devices in a control network. Feature: Power supply range of 19-300 Vdc and 40-250 Vac with 50/60 Hz operation. Benefit: Retrofits and new installations across mixed voltage environments without custom power supplies. Application: Enables easy integration into existing plant power architectures while preserving protection topology. Feature: I/O options including URTD Interface, Trip Coil Monitor, Sensitive Ground Input, and IRIG-B. Benefit: Streamlined trip-control signaling and enhanced time synchronization, reducing miscoordination risks. Application: Critical for large-scale transformer protection schemes requiring precise coordination and monitoring. Feature: Conformal coating and removable terminals with projection mounting. Benefit: Improves reliability in challenging environments and simplifies field wiring and maintenance. Application: Useful in harsh industrial settings and retrofit projects where serviceability matters. Feature: Sensing inputs cover Voltage Protection and Metering, Differential Protection, Current Protection and Metering, and Power Protection and Metering. Benefit: Comprehensive protection coverage within a single relay minimizes components and simplifies testing. Application: Transformer protection in substations and heavy industries where multiple protection functions are required from one device.
Get a Quick Quote for a Eaton ETR-5000-2B2BB1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2B2BB1?
Enquire Now
FAQs
Install the relay using its projected mounting with removable terminals for straightforward wiring. Connect eight digital inputs, nine digital outputs, and two analog I/O according to your protection scheme. Power the unit from 19-300 Vdc or 40-250 Vac and configure RS485 communication for Modbus RTU or DNP3 RTU, following the Eaton datasheet for termination and addressing.
The relay supports Modbus RTU over RS485 and DNP3 RTU over RS485, enabling straightforward SCADA integration. Map input/output points, configure protection logic, and enable polling for status, alarms, and metering data. Ensure proper baud rate, line termination, and network addressing to avoid communication delays and data loss.
The device includes Voltage Protection and Metering, Differential Protection, Current Protection and Metering, and Power Protection and Metering. These functions support fast tripping for abnormal conditions, provide event logging for fault analysis, and help minimize fault propagation in critical transformer networks.
The relay accepts a power supply range of 19-300 Vdc or 40-250 Vac and operates at 50/60 Hz. It features removable terminals and projection mounting for easy field wiring and installation. Conformal coating enhances reliability in challenging environments, making it suitable for retrofit and new-build transformer protection projects.
Eaton provides a standard warranty of one year from installation or eighteen months from shipment, whichever occurs first. For compliance documentation, firmware updates, or extended service terms, contact Eaton technical support or your authorized distributor to confirm regional terms and replacement guidelines.