Eaton ETR-5000-2B2CA0 Transformer Relay - Modbus TCP
Part Number: ETR-5000-2B2CA0
Quick Summary
Eaton transformer relay protects transformers in electrical plants and substations, delivering reliable protection and precise control for critical assets. Configuring protection logic and remote fault monitoring can be time consuming without a unified, scalable solution that harmonizes inputs, outputs, and alarms. Typical industry certifications include CE marking, SIL ratings, and IP ratings; verify exact scope with Eaton to ensure site-specific compliance. Designed for transformer protection, monitoring, and metering, it suits OEMs, engineering contractors, and utility-scale installations seeking operational certainty. With Modbus TCP over Ethernet and flexible IO configurations, you gain real-time visibility, faster fault isolation, and lower maintenance costs across fleets.
Product Information
Extended Description
ETR-5000-2B2CA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor,Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B2CA0
UPC
786679157244
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Trip Coil Monitor URTD Interface Sensitive Ground Input IRIG-B
Modbus / DNP3 RTU
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Differential Protection Current Protection and Metering Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
E-series protective relays
E-series protective relays
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Eaton Specification Sheet - ETR-5000-2B2CA0
Feature: 8 digital inputs and 9 digital outputs with 2 analog inputs and 2 analog outputs. Business Impact: Provides comprehensive sensing and control for transformer protection, enabling quick trip decisions and accurate metering. Application: Ideal for transformer protection relays in substations and industrial transformer apps requiring integrated protection and monitoring. Long-tail keywords: transformer protection relay with digital IO, Modbus TCP protection, metering capable relay. Feature: Universal power supply range 19-300 Vdc and 40-250 Vac with 50/60 Hz capability. Business Impact: Simplifies installation and retrofit, reducing wiring complexity and the need for multiple power supplies. Application: Retrofit projects and new builds that demand flexible input power. Long-tail keywords: wide input power supply, universal input transformer relay, energy-efficient protection devices. Feature: Communications options including Modbus TCP or DNP3 TCP/UDP over Ethernet RJ-45, URTD interface, IRIG-B, and Sensitive Ground Input. Business Impact: Enables seamless SCADA integration, precise time stamping, and interoperable protection schemes. Application: Substations and OEM controls requiring robust networked protection. Long-tail keywords: Modbus TCP DNP3 compatibility, Ethernet-based relay, time-synchronization interface. Feature: 2 analog inputs, 2 analog outputs, 8 digital inputs, 9 digital outputs, and Zone Selective Interlocking. Business Impact: Supports complex protection coordination and fast selective tripping, reducing outage duration. Application: Medium to large transformer protection schemes in industrial facilities. Long-tail keywords: zone selective interlocking, differential protection inputs, digital I/O protection. Feature: Removable terminals and semi-flush mounting with ETR-4000 base compatibility; optional Trip Coil Monitor and URTD Interface. Business Impact: Streamlines maintenance, upgrades, and field wiring changes; simplifies retrofits. Application: Retrofit projects and new installations seeking a modular, service-friendly architecture. Long-tail keywords: removable terminals, semi-flush mounting, ETR-4000 compatibility.
Get a Quick Quote for a Eaton ETR-5000-2B2CA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2B2CA0?
Enquire Now
FAQs
Begin with securing the unit using its removable terminals and semi-flush mounting layout. Verify the panel has space for the 8 digital inputs, 9 digital outputs, and both analog channels. Connect the power supply within the 19-300 Vdc and 40-250 Vac range, then wire the Ethernet port for Modbus TCP or DNP3. Finally, align base-relay compatibility with the ETR-4000 and perform a checkout of protection logic using Eaton's configuration tools.
Key specs include power supply range of 19-300 Vdc or 40-250 Vac with 50/60 Hz, 8 digital inputs, 9 digital outputs, 2 analog inputs, and 2 analog outputs. The unit also supports Modbus TCP or DNP3 over Ethernet RJ-45, plus optional interfaces like URTD and IRIG-B for time coordination and fault analytics. Current sensing inputs accommodate 5A and 1A ranges as part of measurement capabilities.
Yes. The device is built for transformer protection, monitoring, and metering in utility-scale environments. Its 8/9 IO configuration supports protection schemes, while Modbus TCP or DNP3 integration simplifies SCADA interfacing. The option for Zone Selective Interlocking and Trip Coil Monitor further enhances protective coordination, enabling faster isolation of faulty sections to minimize outages.
The datasheet lists Compliance as 'Contact Manufacturer,' so confirm exact certifications with Eaton for your installation. Industry expectations for transformer protection equipment often include CE marking, SIL ratings, and IP ratings; however, verify the exact scope and any site-specific requirements directly with Eaton prior to procurement and installation.
Maintenance benefits come from modular IO, removable terminals, and base-relay compatibility with the ETR-4000, which simplify upgrades and field diagnostics. The integrated Modbus TCP/DNP3 interface enables remote monitoring and fault analytics, reducing on-site visits. Over time, this leads to lower maintenance costs, improved uptime, and a faster return on investment through optimized protection coordination.