Eaton ETR-5000-2B2CB0 Transformer Relay - Ethernet RJ-45
Part Number: ETR-5000-2B2CB0
Quick Summary
Eaton transformer relay ETR-5000-2B2CB0 delivers transformer protection and monitoring for industrial power systems. Engineers often struggle to coordinate protection signals across distributed equipment while maintaining reliable remote diagnostics. Typical deployments seek CE compliance, SIL readiness, and IP-rated enclosures; verify with the manufacturer. By leveraging Modbus TCP or DNP3 over Ethernet RJ-45, this device enables seamless SCADA integration and centralized fault visibility. With 8 digital inputs, 9 outputs, and a flexible power range, it supports scalable protection architectures across regions and applications, delivering improved reliability, faster fault isolation, and reduced maintenance costs.
Product Information
Extended Description
ETR-5000-2B2CB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz Trip Coil MonitorSensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B2CB0
UPC
786679157268
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Sensitive Ground Input URTD Interface Trip Coil Monitor
Modbus / DNP3 RTU
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Differential Protection Current Protection and Metering Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
E-series protective relays
E-series protective relays
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Eaton Specification Sheet - ETR-5000-2B2CB0
Flexible power and I/O configuration enables tailor-made protection; this reduces wiring complexity and panel footprint, accelerating commissioning in transformer protection schemes. The unit supports a wide power range (19-300 VDC, 40-250 VAC) and handles 8 digital inputs, 9 outputs, plus 2 analog inputs and 2 analog outputs, letting you match protection schemes to machine requirements. This translates to faster deployment across regions with varying supply standards. Industry-leading communication capabilities enable seamless SCADA integration; Modbus TCP or DNP3 over Ethernet RJ-45 supports real-time data exchange, alarms, and metering. Operators gain centralized visibility and faster fault localization, reducing MTTR. The ETR-5000-2B2CB0 also supports remote diagnostics via standard protocols, enabling proactive maintenance. Base relay compatibility with ETR-4000, conformal coated circuit boards, and removable terminals simplify retrofits and field servicing. This means technicians can swap to the new relay without a full panel rewrite, and the conformal coating provides protection in harsh environments. I/O options include Trip Coil Monitor and IRIG-B Sensitive Ground Input for coordinated protection and precise fault isolation. These features enable reliable, repeatable trip schemes essential in transformer protection in utilities and process industries. Compact footprint with 8.06 in depth, 8.7 in height, 9.72 in width, and 9.3 lb weight, combined with Eaton’s warranty, supports straightforward installation and predictable maintenance costs in modern control rooms and outdoor substations.
Get a Quick Quote for a Eaton ETR-5000-2B2CB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2B2CB0?
Enquire Now
FAQs
Begin with the semi-flush mounting option and use the removable terminals to simplify wiring. Confirm compatibility with the ETR-4000 base relay, then wire digital and analog I/O (8 inputs, 9 outputs, 2 analog inputs, 2 analog outputs) to match your protection scheme. Follow OEM guidelines for grounding and diagnostics to ensure reliable operation.
Power supply range is 19-300 VDC or 40-250 VAC, with a 50/60 Hz frequency rating. It provides 8 digital inputs, 9 digital outputs, plus 2 analog inputs and 2 analog outputs. Communication options include Modbus TCP or DNP3 TCP/UDP over Ethernet RJ-45, and it supports protection coordination features via the base ETR-4000.
Ideal for transformer protection in substations and industrial plants, including monitoring and metering functions. Its flexible I/O, robust communication, and compatibility with existing ETR-4000 hardware make it suitable for retrofit projects and new installations requiring scalable protection and remote diagnostics.
Current data indicates compliances should be confirmed with the manufacturer. The product is sold with a standard Eaton warranty, and CE/SIL/IP certifications should be verified during procurement based on installation location and application requirements.
The relay enables centralized monitoring via Modbus TCP/DNP3, reducing maintenance visits and accelerating fault isolation. Its retrofit compatibility, rugged conformal coating, and removable terminals lower lifecycle costs while improving reliability and uptime for transformer protection schemes.