Eaton ETR-5000-2B2GA0 Transformer Relay - Modbus RTU/RS485

Part Number: ETR-5000-2B2GA0
Manufacturer
Eaton
Part number
ETR-5000-2B2GA0

Quick Summary

ETR-5000-2B2GA0 Eaton transformer relay delivers advanced transformer protection and metering for industrial power systems. Engineers often struggle with reliable protection coordination, scalable communications, and rapid diagnostics in harsh environments. Common industry certifications and standards such as CE, SIL, and IP-rated enclosures support safety, reliability, and environmental resilience. This device combines modular IO, 50/60 Hz operation, and Modbus RTU or DNP3 RTU over RS-485 to streamline integration and reduce total cost of ownership. Turnkey compatibility with Eaton’s ETR-4000 base and a wide power supply range enables faster, safer deployment in both retrofit and new installations.

Product Information

Extended Description

ETR-5000-2B2GA0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over D-SUB/RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, D-Sub / RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz Sensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B2GA0
UPC
786679157916
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Trip Coil Monitor Sensitive Ground Input URTD Interface
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Voltage Protection and Metering Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Modular IO and robust communications enable precise protection logic and flexible plant integration, reducing downtime and enabling rapid fault localization. With 8 digital inputs, 9 outputs, 2 analog inputs, and 2 analog outputs, the device supports comprehensive protection schemes and metering applications for transformers up to 50/60 Hz. The dual power options—19-300 VDC and 40-250 VAC—allow seamless integration into varying plant electrical infrastructures, while removable terminals and semi-flush mounting simplify field installation and maintenance. IRIG-B, Trip Coil Monitor, Sensitive Ground Input, and URTD Interface options provide extended diagnostics and fault isolation, minimizing service interruptions in critical power systems. The built-in Modbus RTU or DNP3 RTU over RS-485 ensures easy integration with SCADA, energy meters, and protection relays, reducing commissioning time and integration risk. Compatibility with the ETR-4000 base delivers a proven protection platform with scalable upgrade paths for future protection needs.

Get a Quick Quote for a Eaton ETR-5000-2B2GA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2B2GA0? Enquire Now

FAQs

Begin by evaluating the transformer protection topology and confirm compatibility with the ETR-4000 base. Use the removable terminals for quick field wiring, then connect RS-485 Modbus RTU or DNP3 RTU to your SCADA or PMU system. Ensure the 19-300 Vdc or 40-250 Vac power supply is within spec and verify the semi-flush mounting for secure cabinet deployment. Finally, configure digital and analog IO (8/2) to match your protection, metering, and monitoring requirements, enabling coordinated trips and accurate fault reporting.
Key specs include a dual power range of 19-300 Vdc and 40-250 Vac, 50/60 Hz operation, 8 digital inputs, 9 outputs, 2 analog inputs, and 2 analog outputs. Communications are via Modbus RTU or DNP3 RTU over RS-485, with optional interfaces like IRIG-B, URTD, and Sensitive Ground Input. The device supports transformer protection functions, metering, and zone-selective interlocking in a compact relay package.
Yes. The ETR-5000-2B2GA0 is designed for transformer protection and metering in industrial power systems. Its 8/9 IO, Modbus/DNP3 communications, and flexible power options simplify integration into switchgear and motor control centers. The device supports protection coordination, remote monitoring, and diagnostic capabilities that help minimize unplanned outages while providing scalable protection for evolving plant architectures.
Compliances for this family are provided by the manufacturer. Industry-standard certifications such as CE and IP ratings are commonly pursued for transformer protection relays to ensure safety and environmental suitability; however, confirm specific certifications with Eaton for the exact lot and installation. This approach helps ensure regulatory alignment in your region and facility class.
The device ships with a one-year warranty from installation or an eighteen-month window from shipment, whichever occurs first, per Eaton policy. Its modular IO and removable terminals reduce commissioning and maintenance time. Remote monitoring via Modbus/DNP3 enables proactive fault detection, lowering downtime costs and extending transformer life. The compatibility with the ETR-4000 base supports future upgrades without replacing the entire protection platform.