Eaton Transformer Relay ETR-5000-2B2HB0 - 61850

Part Number: ETR-5000-2B2HB0
Manufacturer
Eaton
Part number
ETR-5000-2B2HB0

Quick Summary

Eaton transformer relay ETR-5000-2B2HB0 provides fast transformer protection for critical power systems in substations and industrial facilities. Engineers often struggle to integrate protection relays into modern digital networks while maintaining reliable visibility across distributed assets. Formal certifications are not listed; confirm CE, SIL, and IP ratings with the manufacturer to ensure regional compliance. Built for industrial automation, it supports 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet, with a flexible power range of 19-300 VDC or 40-250 VAC. This combination delivers stronger uptime, faster fault isolation, and richer metering data, while leveraging the ETR-4000 base for scalable protection. Its conformal coating and removable terminals simplify field installation and long-term maintenance, reducing commissioning time.

Product Information

Extended Description

ETR-5000-2B2HB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B2HB0
UPC
786679158241
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B Sensitive Ground Input Trip Coil Monitor URTD Interface
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Differential Protection Power Protection and Metering Current Protection and Metering Voltage Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature: Communications and protocol support (61850, M-Bus TCP, DNP3 TCP/UDP over Ethernet) → Business Impact → Application: Enables seamless integration with substation automation, SCADA, and energy management systems, improving data accuracy and remote diagnostics for transformer protection in substations and industrial facilities. Feature: Flexible power supply range (19-300 VDC, 40-250 VAC) and 50/60 Hz operation → Business Impact → Application: Supports diverse plant electrical architectures and grid connection standards, reducing wiring changes during upgrades and enabling rapid deployment in mixed-voltage environments. Feature: I/O capability (8 inputs, 9 outputs; 2 analog inputs, 2 analog outputs) → Business Impact → Application: Facilitates complex protection schemes, metering, and control signaling; ideal for differential and power protection with precise trip coordination. Feature: Base compatibility and rugged build (ETR-4000 base, conformal coating, removable terminals) → Business Impact → Application: Enables upgrade paths from existing relays, improves field reliability in harsh environments, and speeds installation and maintenance. Feature: Protection features (Differential Protection, Power Protection and Metering, Current/Voltage Protection and Metering; Zone Selective Interlocking) → Business Impact → Application: Delivers fast fault isolation and coordinated trip schemes for transformer reliability in both substations and industrial plants.

Get a Quick Quote for a Eaton ETR-5000-2B2HB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2B2HB0? Enquire Now

FAQs

The ETR-5000-2B2HB0 uses removable terminals and semi-flush mounting for straightforward panel installation. It offers 8 digital inputs, 9 outputs, and 2 analog inputs/outputs, with a 19-300 VDC or 40-250 VAC power range. The base relay is ETR-4000, enabling an upgrade path; plan for conformal coating where environmental protection is required and consider optional IRIG-B interfaces for time synchronization.
This transformer relay supports 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet RJ45, with Modbus/DNP3 compatibility where applicable. It provides 2 analog inputs, 2 analog outputs, 8 digital inputs, and 9 digital outputs, enabling integrated protection, metering, and remote monitoring within substation networks and industrial automation environments.
Yes. It offers differential protection, power protection and metering, current/voltage protection and metering, and zone selective interlocking (2). Its conformal-coated circuit boards and removable terminals enhance reliability in harsh environments, while Ethernet-based communications support fast data transfer and fault coordination across substations and plant networks.
Key specs include a power supply range of 19-300 VDC or 40-250 VAC and 50/60 Hz operation. It features 8 inputs, 9 outputs, 2 analog inputs, 2 analog outputs, and 2 current sensing inputs. The device supports 61850, M-Bus TCP, DNP3 TCP/UDP, and removable terminals for simplified wiring and maintenance.
Warranty terms follow Eaton policy 25-000, offering one year from installation or 18 months from shipment, whichever occurs first. For compliance and certification details, customers should contact the manufacturer. Eaton provides specification sheets and product data to support installation, commissioning, and long-term maintenance planning.