Eaton ETR-5000-2B2KA1 Transformer Relay - 50/60 Hz

Part Number: ETR-5000-2B2KA1
Manufacturer
Eaton
Part number
ETR-5000-2B2KA1

Quick Summary

ETR-5000-2B2KA1 transformer relay provides advanced transformer protection for industrial power systems. Manufacturers often struggle to coordinate protection across critical transformers while integrating modern digital monitoring with legacy equipment. In practice, this model supports robust protection coordination, scalable I/O, and flexible communications, helping reduce outage impact and streamline maintenance. While certifications vary by region, transformer protection relays commonly align with CE marking, SIL-rated protection logic, and IP-rated enclosures; verify the exact certifications with Eaton for this model. This device also enables seamless SCADA integration and precise event logging through Modbus and DNP3 TCP over fiber, delivering clear business value in reliability, uptime, and operational insight.

Product Information

Extended Description

ETR-5000-2B2KA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground InputTrip Coil Monitor
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B2KA1
UPC
786679155561
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
None
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input URTD Interface IRIG-B Trip Coil Monitor
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Differential Protection Current Protection and Metering Voltage Protection and Metering Power Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Feature → Business Impact → Application: Flexible I/O and base-relay compatibility; 8 digital inputs and 9 outputs with 2 analog inputs and 2 analog outputs provide rich protection logic and metering capabilities, reducing external I/O wiring and enabling faster protection decisions for transformer assets. This supports transformer protection and monitoring in substations and industrial plants. Feature → Business Impact → Application: Wide power-supply range and mounting ease; 19-300Vdc/40-250Vac power with projection mounting and removable terminals simplifies retrofit and new installs across varied supply environments, lowering installation time and spare-part diversity. Application: Retrofit projects and greenfield installations in power distribution and manufacturing facilities. Feature → Business Impact → Application: Comprehensive protection and metering functions; differential protection, current/voltage/power protection and metering, plus zone selective interlocking and trip coil monitoring enable coordinated protection schemes, faster fault isolation, and improved reliability in critical transformer circuits. Application: Advanced transformer protection in substations and process industries. Feature → Business Impact → Application: Robust communications and time synchronization; Modbus/DNP3 TCP over LC duplex fiber Ethernet with IRIG-B time sync ensures accurate event logging and seamless SCADA integration, reducing MTTR and improving fleet-wide visibility. Application: Remote monitoring and control of transformer assets. Feature → Business Impact → Application: Easy installation and maintenance; removable terminals and compatible base-relay architecture (ETR-4000) shorten commissioning and simplify field maintenance. Application: Efficient lifecycle management for large transformer parks.

Get a Quick Quote for a Eaton ETR-5000-2B2KA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2B2KA1? Enquire Now

FAQs

Begin by mapping the eight digital inputs, two analog inputs, and two analog outputs to your protection logic and metering requirements. Utilize the ETR-4000 base compatibility to replace or upgrade legacy relays without major wiring changes. Leverage zone selective interlocking and trip coil monitoring to coordinate fast fault clearing, while ensuring the Modbus or DNP3 TCP interfaces align with your SCADA network for reliable supervision.
The unit provides eight digital inputs, nine digital outputs, two analog inputs, and two analog outputs. This supports differential, current, voltage, and power protection with embedded metering. In practice, you can implement sequential tripping, alarm signaling, and metered power parameters, delivering richer visibility and faster decision-making in transformer protection schemes.
Yes. The ETR-5000-2B2KA1 supports Modbus and DNP3 TCP over LC duplex fiber optic Ethernet, enabling reliable remote monitoring and control. This integration helps align protection events with SCADA dashboards, supports time-stamped archiving via IRIG-B, and improves coordination across distributed transformer assets.
Yes. The relay includes Zone Selective Interlocking (2) and Trip Coil Monitor capabilities, enabling faster protection coordination and safer, targeted clearance of faults. This is particularly valuable in multi-transformer configurations where selective tripping reduces system disruption and improves reliability.
The product carries Eaton’s standard warranty policy with terms specified by policy 25-000, typically one year from installation or eighteen months from shipment, whichever occurs first. For ongoing maintenance, consult Eaton’s published specification sheets and available training resources, and rely on manufacturer-originated documentation (e.g., the ETR-5000-2B2KA1 datasheet) for service intervals and part recommendations.