Eaton ETR-5000-2B3FB0 Transformer Relay - Modbus RTU
Part Number: ETR-5000-2B3FB0
Quick Summary
Eaton transformer relay is a transformer protection device with integrated monitoring for electrical distribution applications. Engineers face the challenge of wiring complexity and integration across protection, metering, and communication, which can lead to downtime. When selecting a relay for transformer protection, verify certifications such as CE marking for electrical safety, SIL readiness for critical protection, and IP enclosure protection as appropriate. The ETR-5000-2B3FB0 supports Modbus RTU or DNP3 RTU over fiber, enabling scalable, secure communication and remote diagnostics while reducing wiring and installation costs. This combination delivers robust protection and valuable insights for OEMs and utilities alike.
Product Information
Extended Description
ETR-5000-2B3FB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU , 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil MonitorSensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B3FB0
UPC
786679156865
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over Fiber Optic ST
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface Trip Coil Monitor Sensitive Ground Input IRIG-B
Modbus / DNP3 RTU
over fiber optic ST
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Power Protection and Metering Current Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Interfacing with an Eaton E-Series Relay, Step 5: Monitoring with PowerPort-E
Eaton Specification Sheet - ETR-5000-2B3FB0
Feature → Business Impact → Application: 8 digital inputs and 9 digital outputs provide comprehensive I/O for digital protection logic and command signaling, enabling sophisticated protection schemes and precise fault isolation in substations and industrial transformers. This reduces fault duration and improves system availability in critical distribution networks. Feature → Application: 2 analog inputs and 2 analog outputs alongside Modbus RTU or DNP3 RTU over fiber enables high-fidelity metering and remote control, streamlining SCADA integration and enabling proactive asset management across multiple sites. Feature → Application: Power supply range of 19-300 VDC or 40-250 VAC at 50/60 Hz ensures compatibility with diverse plant electrical architectures, minimizing field rework and simplifying retrofits in aging fleets. Feature → Application: Conformal coating on circuit boards and removable terminals enhance reliability in harsh environments and simplify commissioning, reducing maintenance costs and field downtime. Feature → Application: URTD interface options, Trip Coil Monitor, and Sensitive Ground Input offer flexible protection logic and fast fault clearance, improving protection performance for transformer banks and feeder transformers. Feature → Application: Semi-flush mounting and a compact form factor (dimensions around 9.72 in W x 8.7 in H x 8.06 in D) with a 9.3 lb weight supports quick installation in existing cabinets and minimizes rack space while maintaining accessibility for diagnostics.
Get a Quick Quote for a Eaton ETR-5000-2B3FB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2B3FB0?
Enquire Now
FAQs
The ETR-5000-2B3FB0 uses removable terminals and supports semi-flush mounting for straightforward field deployment. It references the base ETR-4000 family and is designed for integration with standard transformer protection schemes. Ensure panel space accommodates its 9.72 in width, 8.7 in height, and 8.06 in depth, and verify wiring for 8 digital inputs and 9 outputs, plus 2 AI/2 AO before commissioning.
The unit provides 8 digital inputs, 9 digital outputs, 2 analog inputs, and 2 analog outputs to support complex protection and metering logic. Communications include Modbus RTU or DNP3 RTU over fiber optic ST, enabling secure SCADA integration and remote diagnostics across distributed transformers.
Yes. The ETR-5000-2B3FB0 is purpose-built for transformer protection and monitoring in electrical distribution. Its 50/60 Hz capability, wide power-supply range (19-300 VDC / 40-250 VAC), and multi-IO configuration support protective relaying, metering, and interlocking within substations, OEM panels, and transformer banks, reducing downtime and improving fault response.
Compliance details are provided by the manufacturer. The datasheet notes 'Compliances: Contact Manufacturer,' so verify CE, IP rating, SIL readiness, or other regulatory standards directly with Eaton to ensure alignment with your project requirements and local codes.
Warranty is Eaton’s standard policy: one year from installation or eighteen months from shipment, whichever occurs first. By consolidating protection, metering, and remote communications in a single device, the ETR-5000-2B3FB0 reduces wiring complexity, speeds installation, lowers maintenance costs, and minimizes transformer-related downtime, delivering measurable total cost of ownership savings.