Eaton ETR-5000-2B3GA1 Transformer Relay - 50/60 Hz RS-485
Part Number: ETR-5000-2B3GA1
Quick Summary
The Eaton transformer relay ETR-5000-2B3GA1 provides robust transformer protection for industrial power distribution. Many engineers struggle to diagnose faults quickly and integrate protection relays with Modbus RTU or DNP3 networks across RS-485 interfaces. Compliance details are not explicitly listed; verify CE/SIL/IP ratings with the manufacturer for your region. This unit supports Modbus RTU or DNP3 RTU over RS-485 and operates on a wide power range of 19-300 Vdc or 40-250 Vac at 50/60 Hz, with 8 digital inputs and 9 outputs, plus analog channels for versatile protection schemes. The combination of broad I/O, time-based features, and Eaton’s warranty helps manufacturers reduce panel count, improve MTTR, and ensure reliable protection in OEM equipment and automation panels.
Product Information
Extended Description
ETR-5000-2B3GA1 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, D-Sub/RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input,
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B3GA1
UPC
786679156889
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
URTD Interface IRIG-B Trip Coil Monitor Sensitive Ground Input
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Voltage Protection and Metering Differential Protection Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Projection
Voltage sensing inputs
1
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Power metering, monitoring and diagnostics products for OEMs
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Specification Sheet - ETR-5000-2B3GA1
Feature → Business Impact → Application: Flexible I/O with 8 digital inputs, 9 outputs and 2 analog inputs/2 analog outputs enables multi-logic protection schemes and precise metering, reducing wiring complexity and panel size while increasing diagnostic capability for transformers in OEM equipment and substations. This translates to faster commissioning, lower installation costs, and improved fault visibility during operation. Feature → Business Impact → Application: RS-485 communication supporting Modbus RTU or DNP3 RTU over D-SUB interfaces simplifies integration with SCADA and energy-management systems, shortening project timelines and ensuring consistent data across plant networks for OEMs, panel builders, and integrators. Feature → Business Impact → Application: Wide power supply range (19-300 Vdc, 40-250 Vac) and 50/60 Hz compatibility provide regional flexibility, reducing the need for multiple part numbers and enabling seamless deployment in diverse transformer configurations and global sites. Feature → Business Impact → Application: Projection mounting and removable terminals accelerate field installation and serviceability, decreasing downtime during upgrades and enabling rapid replacement in retrofit projects. Feature → Business Impact → Application: I/O options including URTD Interface, IRIG-B, Trip Coil Monitor, and Sensitive Ground Input support advanced protection scenarios such as time synchronization, trip verification, and enhanced fault discrimination in transformer protection schemes. Feature → Business Impact → Application: Zone selective interlocking, current sensing inputs and extensive protection channels deliver accurate protection coordination and metering, supporting compliance with utility and OEM testing protocols while lowering total cost of ownership.
Get a Quick Quote for a Eaton ETR-5000-2B3GA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2B3GA1?
Enquire Now
FAQs
The ETR-5000-2B3GA1 supports 8 digital inputs, 9 outputs, 2 analog inputs and 2 analog outputs, plus a 19-300 Vdc / 40-250 Vac power range, enabling seamless integration with common transformer protection schemes. Removable terminals and projection mounting simplify field wiring and retrofit installations, reducing commissioning time and risk.
Key specs include 8 digital inputs, 9 outputs, 2 analog inputs, 2 analog outputs, current sensing inputs (2), and a wide supply range of 19-300 Vdc or 40-250 Vac at 50/60 Hz. I/O options cover URTD Interface, IRIG-B, Trip Coil Monitor, and Sensitive Ground Input, enabling comprehensive protection and time synchronization in demanding environments.
Yes. The relay communicates over RS-485 using Modbus RTU or DNP3 RTU, facilitating straightforward integration with SCADA, energy meters, and industrial automation networks, while minimizing wiring complexity and protocol translation needs.
The data specifies compliance as 'Contact Manufacturer,' so verify CE, SIL, IP ratings, and regional certifications with Eaton before procurement to ensure alignment with your regional standards and safety requirements.
With eight digital inputs, nine outputs, robust RS-485 communication, and versatile protection features, the ETR-5000-2B3GA1 reduces wiring and panel count, lowers MTTR through faster fault diagnosis, and supports long-term maintenance via removable terminals and clear diagnostics, delivering a favorable total cost of ownership for OEM panels and substations.