Eaton transformer relay ETR-5000-2B3HB0 delivers advanced transformer protection for substations and industrial plants. Engineers often wrestle with integrating protection logic across multiple protocols while minimizing downtime. This model supports 61850, MBus TCP, and DNP3 TCP/UDP over Ethernet, with conformal coating and rugged construction; verify CE, SIL, and IP options in the specific datasheet. By combining flexible I/O, Ethernet-based communication, and a wide power supply range, it reduces wiring complexity, speeds fault isolation, and lowers maintenance costs for mission-critical transformer protection deployments.

Product Information

Extended Description

ETR-5000-2B3HB0 Eaton: Eaton, transformer relay, ETR-4000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz ,Sensitive Ground Input
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B3HB0
UPC
786679157282
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
Conformal Coated Circuit Boards
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
Sensitive Ground Input IRIG-B Trip Coil Monitor URTD Interface
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Differential Protection Voltage Protection and Metering Current Protection and Metering
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature: Ethernet-based protection with 61850, MBus TCP, and DNP3 TCP/UDP over Enet RJ45. Business Impact: Simplifies integration with modern SCADA and substation automation while ensuring fast, coordinated tripping and monitoring. Application: Transformer protection in substations and industrial facilities, enabling seamless interoperability and reduced engineering effort. Long-tail keywords: 61850 protection relay, DNP3 TCP/UDP Ethernet, Ethernet-enabled protection. Feature: 8 digital inputs, 9 digital outputs, 2 analog inputs, 2 analog outputs. Business Impact: Consolidates protection logic and metering signals in a single panel, cutting external I/O hardware and wiring costs. Application: Comprehensive protection schemes for transformer banks with streamlined wiring diagrams. Long-tail keywords: transformer relay I/O count, AI/AO/DI/DO integration, metering and protection I/O. Feature: Wide power supply range 19–300 Vdc and 40–250 Vac, 50/60 Hz. Business Impact: Enables operation across diverse plant voltages and control schemes, reducing part diversity and stocking needs. Application: Mixed-voltage facilities and retrofit projects where new relays must align with existing controls. Long-tail keywords: wide voltage input, dual voltage compatibility, 50/60 Hz operation. Feature: I/O options including Sensitive Ground Input, IRIG-B, Trip Coil Monitor, URTD Interface, and conformal coating. Business Impact: Increases protection topology flexibility, reliability in harsh environments, and ease of field deployment. Application: Outdoor substations, harsh-environment installations, and precise timing/monitoring setups. Long-tail keywords: IRIG-B timing, URTD interface, conformal coated boards. Feature: Base compatibility with ETR-4000 and modular communication options. Business Impact: Facilitates migration or upgrade paths without complete system overhaul, preserving legacy investments. Application: Retrofit projects and scalable transformer protection architectures. Long-tail keywords: ETR-4000 integration, migration path, scalable transformer protection.

Get a Quick Quote for a Eaton ETR-5000-2B3HB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2B3HB0? Enquire Now

FAQs

Begin with a semi-flush mounting approach and secure removable terminals for easy wiring. Follow Eaton’s installation guide to connect 8 digital inputs, 9 outputs, and the two analog channels, then integrate 61850 or DNP3/TCP communication over Ethernet RJ45. Ensure proper power supply within 19–300 Vdc or 40–250 Vac and verify grounding practices to minimize nuisance trips and improve reliability.
Its multi-protocol Ethernet communications (61850, MBus TCP, DNP3 TCP/UDP) enable seamless SCADA integration, while the 8 DI/9 DO and 2 AI/2 AO inputs support comprehensive protection and metering. The rugged construction and optional conformal coating improve reliability in outdoor or harsh environments, reducing maintenance cycles and enabling faster fault isolation in substations.
Yes. The productline explicitly lists 61850 and DNP3 TCP as communication options over Ethernet RJ45, with MBus TCP as an additional protocol. This enables interoperable protection schemes, remote monitoring, and streamlined integration with modern SCADA and protection systems.
The relay provides 8 digital inputs, 9 digital outputs, and 2 analog inputs plus 2 analog outputs. Configuration is performed via Eaton’s interface tools, mapping inputs and outputs to protection logic, metering, and alarms. This setup supports flexible transformer protection schemes while minimizing external I/O modules and wiring.
Eaton’s standard warranty for this product follows policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. For technical support, consult Eaton’s datasheet and regional support channels to access software updates, field service options, and replacement part availability.