Eaton transformer relay ETR-5000-2B3KA0 - URTD Interface

Part Number: ETR-5000-2B3KA0
Manufacturer
Eaton
Part number
ETR-5000-2B3KA0

Quick Summary

Eaton transformer relay ETR-5000-2B3KA0 provides advanced transformer protection and metering for industrial and utility power systems. Engineers often struggle to integrate diverse sensing inputs and maintain reliable trip logic across wide power ranges without adding complexity or cost. Certification details vary by installation; verify CE/UL/IP ratings in the official Eaton datasheet to ensure compliance for your region. This device features interfaces like IRIG‑B, URTD, and Trip Coil Monitor with removable terminals, enabling straightforward field wiring. The combination of flexible I/O, modular base compatibility, and Ethernet communications supports faster deployment, easier OEM integration, and robust protection in transformer schemes. It also combines metering capabilities with protection to optimize asset performance and uptime.

Product Information

Extended Description

ETR-5000-2B3KA0 Eaton: Eaton transformer relay, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 9, Removable, Transformer, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor,Sensitive Ground Input, Trip Coil Monitor, Sensitive Ground Input, IRIG-B, URTD Interface
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2B3KA0
UPC
786679155851
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Transformer
Type
Transformer relay
Product Category
Transformer protection relay
Analog inputs
2
Analog outputs
2
Base relay
ETR-4000
Conformal coating
None
Current sensing inputs
2
Digital inputs
8
Digital outputs
9
I/O options
IRIG-B URTD Interface Sensitive Ground Input Trip Coil Monitor
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Voltage Protection and Metering Power Protection and Metering Differential Protection
Zone selective interlocking
2
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
8
Number of outputs
9
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Feature: Flexible I/O and modular base. Business Impact: Simplifies protection logic, reduces cabling complexity, and shortens commissioning time for OEMs. Application: Substation and transformer protection where 8 digital inputs, 9 outputs, and 2 analog channels are required. Feature: Broad power range and frequency tolerance. Business Impact: Enables operation from 19-300Vdc or 40-250Vac with 50/60 Hz, reducing the need for multiple accessories and improving grid compatibility. Application: Plants with mixed power rails and legacy equipment benefit from a single relay platform. Feature: Advanced I/O options. Business Impact: IRIG-B, URTD Interface, Sensitive Ground Input, and Trip Coil Monitor provide precise timing, robust grounding detection, and fault signaling—lowering mis-trip risk. Application: Critical transformer protection schemes and diagnostics in harsh environments. Feature: Communication and interoperability. Business Impact: Modbus/DNP3 TCP over LC duplex fiber enables secure, long-distance integration with SCADA and EMS, improving data visibility and control. Application: OEMs and utilities implementing integrated protection architectures. Feature: Removable terminals and mechanical design. Business Impact: Streamlined maintenance and rework in the field, reducing downtime during upgrades or testing. Application: Retrofit projects and OEM panel builds where quick wiring is essential. Feature: Comprehensive diagnostics. Business Impact: Trip Coil Monitor and embedded metering support enhance fault analysis and asset utilization, driving better maintenance planning. Application: Transformer health monitoring in asset-intensive operations.

Get a Quick Quote for a Eaton ETR-5000-2B3KA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ETR-5000-2B3KA0? Enquire Now

FAQs

Begin by removing the terminal blocks to access the removable terminals, then mount the ETR-5000-2B3KA0 in the panel using the semi-flush mounting approach. Connect the 8 digital inputs, 2 analog inputs, 2 analog outputs, and 9 outputs to your protection logic and metering scheme. Use the IRIG-B or URTD interfaces for timing and synchronization as needed, and ensure the power supply is within 19-300 Vdc or 40-250 Vac. This approach minimizes wiring complexity and supports quick field upgrades.
Verify the power supply range of 19-300 Vdc and 40-250 Vac, the 50/60 Hz frequency rating, and the phase current options of 5 A and 1 A. Confirm 8 digital inputs, 2 analog inputs, 2 analog outputs, and 9 digital outputs align with your control logic. Also ensure the Modbus/DNP3 TCP over fiber interface is compatible with your SCADA network.
Yes. The device is designed as a transformer protection relay with integrated metering capabilities. Its 8/9 IO configuration supports essential protection schemes, while 2 analog inputs/outputs enable metering data. Interfaces like IRIG-B and URTD support precise timing and input conditioning, making it suitable for substation protection and monitoring tasks when paired with compatible SCADA systems.
Certification specifics are documented in the official Eaton specification sheet. Compliance details, including CE/UL or IP ratings, vary by installation and region. Refer to the Eaton datasheet (ETR-5000-2B3KA0.pdf) or contact Eaton support to confirm regional approvals before procurement.
The product follows Eaton Selling Policy 25-000, offering a one-year warranty from the date of installation or eighteen months from shipment, whichever occurs first. This warranty covers manufacturing defects and supports post-installation maintenance planning, helping protect your ROI when deployed in critical transformer protection applications.