Eaton ETR-5000-2F0HA0 Transformer Relay - 61850 Ethernet
Part Number: ETR-5000-2F0HA0
Quick Summary
The Eaton transformer relay ETR-5000-2F0HA0 delivers advanced transformer protection and monitoring for industrial and utility power systems. Operators often struggle with weaving together protection schemes and achieving reliable communications across multiple networks. The device supports IEC 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet, with a wide power input range of 19-300 VDC and 40-250 VAC at 50/60 Hz. While the provided data does not specify CE, SIL, or IP certifications, the Ethernet-ready design and modular input/output architecture align with common industry expectations for transformer protection relays. This combination enables scalable protection, metering, and remote diagnostics, delivering measurable value in asset reliability and operational efficiency.
Product Information
Extended Description
ETR-5000-2F0HA0 Eaton: Eaton, transformer relay, ETR-5000, Transformer protection relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5 A, 1 A, 40-250 Vac, 19-300 Vdc, 8, 9,Transformer, over Ethernet RJ-45, 19-300Vdc, 50/60 Hz, 40-250V ac
Product Name
Eaton transformer relay
Catalog Number
ETR-5000-2F0HA0
UPC
786689640750
Product Length/Depth
8.06 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.3 lb
Product Category
Transformer protection relay
Base relay
ETR-4001
Communication
61851 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
2
Digital inputs
16
Digital outputs
16
I/O options
URTD Interface Trip Coil Monitor IRIG-B
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Differential Protection Power Protection and Metering Voltage Protection and Metering
Number of inputs
16
Number of outputs
16
Power supply range
19-300Vdc, 40-250Vac
Frequency rating
50/60 Hz
Power consumption
40-250 Vac, 19-300 Vdc
Number of inputs
16
Number of outputs
16
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Terminals
Removable
Mounting method
Semi-flush
Voltage sensing inputs
1
Terminals
Removable
Power metering, monitoring and diagnostics products for OEMs
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Distribution and Transformer Relays
Eaton Specification Sheet - ETR-5000-2F0HA0
Feature: Ethernet-based protection communications. Business Impact: Enables seamless interoperability across substation networks, faster fault isolation, and easier remote diagnostics. Application: Transformer protection in energy facilities requiring IEC 61850, M-Bus TCP, or DNP3 TCP/UDP over Ethernet. Feature: Dense I/O with 16 inputs and 16 outputs plus 2 current sensing inputs. Business Impact: Reduces panel footprint and wiring costs while enabling complex protection logic and metering. Application: Coordinated protection schemes and metering in transformer bays with room for expansion. Feature: Wide power supply range and 50/60 Hz operation (19-300 VDC, 40-250 VAC). Business Impact: Flexible installation across sites with varying supply environments; simplifies maintenance with removable terminals. Application: Retrofit or new builds in industrial plants. Feature: Base relay compatibility and I/O options (ETR-4001, URTD Interface, Trip Coil Monitor, IRIG-B). Business Impact: Easy upgrades and seamless integration with legacy protection schemes and monitoring. Application: Modernizing transformer protection without replacing existing systems. Feature: Comprehensive sensing and protection coverage (Differential, Power, Voltage Protection and Metering). Business Impact: Improves protection coordination and compliance, reduces outage durations, and supports accurate metering. Application: Substations and plant electrical rooms needing reliable transformer protection and energy accounting. Feature: Integrated metering, monitoring, and diagnostics with Ethernet access. Business Impact: Accelerates maintenance decisions, enables predictive maintenance, and lowers total cost of ownership through data-driven insights. Application: OEMs and service providers deploying scalable protection with SCADA integration.
Get a Quick Quote for a Eaton ETR-5000-2F0HA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ETR-5000-2F0HA0?
Enquire Now
FAQs
Plan for semi-flush mounting and use of removable terminals to simplify wiring and future maintenance. With 16 digital inputs and 16 outputs, map protection logic and metering needs carefully to minimize crossover and avoid channel conflicts. Ensure proper Ethernet cabling for IEC 61850, M-Bus TCP, or DNP3 TCP/UDP communications and adequate clearance for access to the URTD/IRIG-B options.
The relay provides Ethernet-based communications with support for IEC 61850, M-Bus TCP, and DNP3 TCP/UDP over an RJ45 interface. This enables compatibility with modern substation and plant SCADA systems, simplifies data collection from metering and protection functions, and reduces integration time for OEMs deploying multi-protocol protection schemes.
Yes. The product listing includes I/O options such as URTD Interface, Trip Coil Monitor, and IRIG-B, and it is designed to work with the ETR-4001 base relay. This enables enhanced trip circuit monitoring, reliable time synchronization for protection sequences, and smoother upgrades from older protection panels while preserving existing trip coil arrangements.
The ETR-5000-2F0HA0 supports a wide power range of 19-300 VDC and 40-250 VAC, with a frequency rating of 50/60 Hz. It provides 16 inputs and 16 outputs, plus 2 current sensing inputs. Terminals are removable for easier installation and maintenance, and the unit is designed for semi-flush mounting in standard electrical enclosures.
Integrated metering, monitoring, and diagnostics streamline maintenance planning and enable proactive servicing. Ethernet-based communications reduce wiring complexity and enable remote diagnostics, which can shorten MTTR and improve asset reliability. Over time, these features contribute to lower total cost of ownership through improved protection coordination and data-driven optimization of transformer assets.